首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   11篇
  免费   1篇
  国内免费   2篇
测绘学   2篇
地球物理   6篇
地质学   2篇
自然地理   4篇
  2015年   1篇
  2011年   1篇
  2010年   1篇
  2009年   1篇
  2007年   1篇
  2004年   2篇
  2002年   1篇
  1999年   1篇
  1998年   1篇
  1993年   2篇
  1990年   1篇
  1989年   1篇
排序方式: 共有14条查询结果,搜索用时 256 毫秒
1.
A three-dimensional ultrasonic modelling was used to study the Rayleigh waves reflected from a thin low velocity vertical layer and those transmitted through the same zone. The reflection and transmission coefficients of the Rayleigh waves have been calculated by an approximate method based on the Green function technique. Nonrigid contact boundary conditions were used for the low velocity layer modelling. A rather good correspondence between the theoretical and experimental absolute values of the reflection and the transmission coefficients was obtained. Some discrepancies between experimental and theoretical results, in particular with regard to phase shifts, may be explained by a certain inadequacy of the theoretical model to the low velocity layer investigated by the ultrasonic modelling.  相似文献   
2.
Investigation on Lunar polar area is almost every lunar mission’s primary objective in recent years. The rationale behind it is that illumination and ice resources in this area can be potentially very helpful for constructing lunar human base. In this paper, we analyze microwave radiometric characteristics of the Moon by using the newly acquired Chang’E-1 Lunar Microwave Sounder (CELMS) data. Microwave brightness temperature at Lunar South Pole (LSP) is distributed regularly with a style of "ring-in-ring", decreasing from equator to pole. Regolith temperature gradient is bigger at lunar equator than at polar area. Brightness temperature diurnal difference decreases with observation frequency. Microwave brightness temperature distribution maps at LSP and Lunar North Pole (LNP) have been made based on the analysis. It is found that microwave brightness temperature becomes to synchronize with elevation beyond -85° latitude. This phenomenon is related to lightening condition and indicates temperature distribution at LSP. The brightness temperature anomaly cold points are potentially cold trap areas for water or ice while hot points imply plenty of illumination resources there.  相似文献   
3.
针对标准粒子滤波算法中存在的计算量大和粒子的权值退化的缺陷,将均值漂移算法和PF算法进行融合,设计基于均值漂移搜索算法的粒子滤波新算法。该算法仍遵从粒子滤波算法的计算框架,基本原理是利用MS算法对粒子的聚类作用,将均值漂移思想融合到粒子滤波算法的重要性采样过程中,对粒子集进行确定性搜索,使每个粒子收敛于局部最优值,这样粒子的状态表示更接近真实的状态分布,因此只需较少的粒子数便可达到未嵌入MS的使用大量粒子数的粒子滤波状态估计的性能,从而在缓解粒子的权值退化的同时提高粒子滤波算法的实时性。大量的数值试验和对GPS/DR组合导航数据处理的结果验证了该方法的有效性。  相似文献   
4.
There are many chemical products where product conformity is decided upon by qualitative humanjudgements of overall product quality.Nowadays,quantitative instrumentally determined qualityparameters become available which are intended to replace such qualitative judgements by means ofautomatic decision rules using multivariate specification limits.Six classification methods to derive suchlimits are compared in terms of their power to predict corresponding human judgements on overall colorconformity of 17 dyestuffs based on historical quality data.Standard statistical classification methodsturned out to be unacceptable for the routine generation of decision rules because of the frequent distinctsuboptimality of their predictive power.Instead,a simple non-statistical classification method utilizinga priori knowledge about the underlying data structure yielded uniformly satisfactory decision rules.  相似文献   
5.
Three-Dimensional Gravity Model Applied to Underwater Navigation   总被引:1,自引:0,他引:1  
At present, new integrated navigation, which usesthe location function of reference gravity anomaly map to control the errors of the inertial navigation system (INS), has been developed in marine navigation. It is named the gravity-aided INS. Both the INS and real-time computation of gravity anomalies need a 3-D marine normal gravity model. Conventionally, a reduction method applied in geophysical survey is directiy introduced to observed data processing. This reduction does not separate anomaly from normal gravity in the observed data, so errors cannot be avoided. The 3-D marine normal gravity model was derived from the J2 gravity model, and is suitable for the region whose depth is less than 1000 m.  相似文献   
6.
The paper has developed and proposed a synthesis analysis method based on the robust satellite data analysis technique(RST) to detect seismic anomalies within the bi-angular advanced along-track scanning radiometer(AATSR) gridded brightness temperature(BT)data based on spatial/temporal continuity analysis. The proposed methods have been applied to analyze the Yushu(Qinghai, China) earthquake occurred on 14 th April 2010,and a full AATSR data-set of 8 years data from March2003 to May 2010 with longitude from 91°E to 101°E and latitude from 28°N to 38°N has been analyzed. Combining with the tectonic explanation of spatial and temporal continuity of the abnormal phenomena, the analyzed results indicate that the infrared radiation anomalies detected by the AATSR BT data with nadir view appear and enhance gradually along with the development and occurring of the earthquake, especially along the Ganzi-Yushu fault, Nu River fault and Jiali-Chayu fault; more infrared anomalies along the earthquake fault zone(Lancangjiang fault and Ning Karma Monastery-Deqin fault) are detected using the proposed synthesis analysis method, which can also characterize the activity of seismic faults more precisely.  相似文献   
7.
Exploratory data analysis(EDA)is a toolbox of data manipulation methods for looking at data to seewhat they seem to say,i.e.one tries to let the data speak for themselves.In this way there is hope thatthe data will lead to indications about'models'of relationships not expected a priori.In this respect EDAis a pre-step to confirmatory data analysis which delivers measures of how adequate a model is.In thistutorial the focus is on multivariate exploratory data analysis for quantitative data using linear methodsfor dimension reduction and prediction.Purely graphical multivariate tools such as 3D rotation andscatterplot matrices are discussed after having introduced the univariate and bivariate tools on which theyare based.The main tasks of multivariate exploratory data analysis are identified as'search for structure'by dimension reduction and'model selection'by comparing predictive power.Resampling is used tosupport validity,and variables selection to improve interpretability.  相似文献   
8.
For centuries, explorers and scientists from different countries had made their own conclusions on the source of the Mekong. However, the geographic source of the Mekong is still arguable because of the complexity of the Mekong source water system, inaccessible environment and the varied technologies used by those explorers and scientists. The satellite remote sensing technology has been used to pinpoint the source of the Mekong, associated with the on-the-spot investigations made by the authors in June 1999 and September 2002. The actual length of the Mekong has also been calculated.  相似文献   
9.
In this paper, we report the first wetland mapping of the entire China using Landsat enhanced thematic mapper plus (ETM+) data. These data were obtained from the Global Land Cover Facility at the University of Maryland spanning from 1999 to 2002. A total of 597 scenes of Landsat images were georeferenced and mosaiced. Manual image interpretation of satellite images was aided with elevation data, soil data, land cover/land use data and Google Earth. The minimum mapping unit is 10 pixel × 10 pixel, equivalent...  相似文献   
10.
A brief review of the literature on point estimators in linear calibration problems is undertaken,Supportive evidence for the relative merits of the classical and inverse regression models,drawn in generalfrom the classical inferential and Bayesian approaches,is considered and the criteria for comparison ofthe estimators are discussed with respect to their suitability for certain classes of problems.Theperformance of the estimators is assessed with respect to determining the current value of ‘x’,thepercentage concentration of administered drug levels in blood in this example.No single‘best’methodof estimation appears to hold for all values of the unknown concentration when performance is assessedby criteria based on the mean square error (MSE).However,the inverse estimator would appear to besuperior to the classical for those values of unknown X close to x.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号