首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 23 毫秒
1.
Geoelectrical methods involving electrical resistivity tomography (ERT), self-potential (SP), frequency domain electromagnetic (FDEM), and very low frequency (VLF) methods have been used to provide valuable information in locating a known sulfide ore body in Soap Gulch, Montana. The study develops basis of comparison for the geophysical techniques employed. Ranges of resistivity along the area have been established using interpreted ERT which can help to understand the subsurface distribution of sulfides in the area. A sulfide body was delineated from the survey area corresponding to anomalously low resistivity values on the ERT section, negative SP, and high apparent current density zone in VLF. Depth to the localized ore zone ranges approximately from 10 to 20 m. FDEM data reflect the conductivity distribution of the shallow subsurface (less than 6 m deep); hence, the delineated sulfide zone had minimal contribution to FDEM measurements. The results of the study show that SP, VLF, and ERT methods provide significant information in localizing ore bodies. The survey revealed that the resistivity values obtained from ERT profile corroborate the FDEM, SP, and VLF from the area.  相似文献   

2.
Electrical resistivity imaging is a widely used tool in near surface geophysical surveys for investigation of various geological, environmental and engineering problems including landslide. In this study, an electrical resistivity tomography (ERT) survey was conducted in a landslide area, located in the Söke district of Aydın, Turkey. In 2003, the Neogene-aged units on the slope next to a newly built school building became unstable due to an excavation work and moved after a heavy rainfall. The resulting landslide partly covered the school. The authors carried out a 2-D resistivity survey along three profiles over the landslide mass using a Wenner configuration. It yielded useful information about the geometry and characteristics of the landslide. In addition, a 2-D synthetic resistivity modelling study was carried out to understand the response of the resistivity method to a landslide problem before the field surveys. Eight boreholes were also drilled in the landslide area. Both the drilling and resistivity results indicated the presence of a fault in the site. Also, the resistivity data from the line measured along the axis of the landslide revealed the surface of rupture.  相似文献   

3.
代晓光 《地质与勘探》2022,58(4):809-821
地物化综合信息在热液充填型萤石矿找矿的应用探索具有重要意义。本文以冀北步古沟一带萤石找矿为例,通过综合物化探方法进行有效性试验,总结该地区萤石矿地物化找矿技术方法组合。在地质调查基础上,系统开展了1:5万水系沉积物地球化学测量、1:1万土壤剖面测量、高精度磁法测量、天然电场选频测量、电阻率联合剖面测量及高密度电阻率测量等找矿技术方法探索。结果表明,1:5万水系沉积物测量及1:1万土壤剖面测量等化探方法可辅助锁定找矿目标区;高精度磁法及天然电场选频测量,可初步判定断裂的位置;电阻率联合剖面及高密度电阻率法测量可进一步探测含矿断裂构造的位置、产状及延伸。通过以上试验研究,建立了冀北地区萤石矿地物化找矿技术方法组合,经工程验证在研究区内新发现萤石矿点1处,取得了较好的效果。实践表明,该套地物化找矿技术方法组合可进一步指导冀北地区的萤石矿找矿工作。  相似文献   

4.
Self potential (SP) and electrical resistivity tomography (ERT) methods are used together with the results of groundwater samples hydrogeochemical analysis to assess the impact of the water leak from the landfill garbage site at NamSon located in Northern Hanoi on causing pollution to the surrounding environment and affecting geological structure. Selected survey area covers an area of 180 × 300 m lying in the low land of the NamSon site with a slope ranging about 8 m in direction NW–SE. There are three geophysical measurements lines denoted as T1, T2 and T3. Processing 180 SP data points has allowed to draw maps of equipotential epoch in the two periods in 2015 and 2016. The maps show four zones of SP positive anomalies with maximum amplitudes of about +20 mV where the groundwater flow direction is downward and five zones of SP negative anomalies with minimum values in a range from ?180 to ?260 mV where the groundwater flow direction is upward. Resistivity values of the subsurface layers of soils and rocks have been aquired from 2D inverse model for measuring ERT in March 2015 and March 2016. The results of the ERT allowed to define the low resistivity in the range 15–20 Ωm related to leachate plume from NamSon landfill site. Results of the physico-chemical analysis of groundwater samples from the existing six boreholes show increases in concentration of the measured pollutant parameters indicating contamination of the groundwater as a result of solid waste leachate accumulation. This result is affirmative evidence for the survey results by geophysical technique. The rapid decrease in quality of groundwater over the last year is probably due to the influence of the leachate from the NamSon landfill site.  相似文献   

5.
Surface geophysical methods were used to determine the locations of fracture zones in part of the hard rock area in Sonebhadra District of Uttar Pradesh, India. The survey comprises three DC resistivity profile using the gradient profiling technique and ten very low frequency electromagnetic (VLF-EM) traverses profiles. The methods were used over survey lines extending between 200 and 400 m; the results were correlated to locate fracture zones for the purpose of groundwater exploration. Qualitative interpretation of the VLF-EM was carried out using Fraser and Karous–Hjelt filters. The result of the interpretation revealed a number of subsurface zones with high real component current density that defines the potential subsurface features (probably fracture zones). The subsurface feature concurred with the low resistive zones indentified from the gradient resistivity profiling. The zones where further inferred quantitatively using data obtained from DC resistivity sounding at some selected anomalous points. The result obtained proves the efficiency of integrating both methods in detecting fractures zones in hard rock area.  相似文献   

6.
The presence of natural voids and cavities in subsurface karstic limestones causes severe problem for civil engineering and environmental management.The presence of such features hinders the extension of urbanizations particularly in the new metropolitan.The eastern part of Saudi Arabia contains various types of karstic limestone,sinkholes,solution cavities and voids.In this context,geophysical methods particularly electrical resistivity technique is used as a cost-effective solution for investigating subsurface caves,voids,and shallow weathered zones.2-D electrical resistivity data sets have been acquired along seven profiles in the new urbanization at Al Hassa area.Data processing has been carried out taking into consideration the response of synthetic models,which simulates physical models of the most common karstic features in the area.The results are very useful to determine the extension of shallow weathered zones and to locate different cavities underneath them.The hard limestone bedrock can also be detected and traced along the surveyed profiles.  相似文献   

7.
Groundwater is a very important component of water resources in coastal aquifers in Thoothukudi. It has been established that the groundwaters in the coastal zone of the Zirconium Complex, Pazhayakayal, Thoothukudi district, Tamilnadu, India, are subjected to wave and tidal impact. The groundwater quality was studied by hydrogeological methods, 2D electrical resistivity imaging (ERI) techniques (six profiles), 11 Wenner vertical electrical sounding (VES), and well log analysis. Also, nine geochemical water samples were taken from the study area. The 2D ERI and VES surveys were carried out using WGMD-4 Ltd., Chennai, resistivity meter, multicore cable, and multielectrodes with Wenner array. The collected resistivity data were interpreted using the Res2DINV software. The research shows that the groundwaters are the result of the paleoriver flow along the Tamirabarani Channel in the western area and of the seawater intrusion in the eastern area. The fresh water is characterized by resistivity of about 10–100 Ohm?m in the study area. The resistivity of 10–50 Ohm?m indicates that the subsurface section is made up of sand, clay, and caliche. Resistivity values of more than 200 Ohm?m are specific to sand dunes. The very low resistivity (<5 Ohm?m) layer might be due to the seawater intrusion in the study area. Six water samples from the well drilled in the coastal area were analyzed, which made it possible to determine the concentrations of major and trace elements in the groundwaters. These data were used to establish the seawater intrusion and coastal environment characteristics in the study area.  相似文献   

8.
The geophysical characterization of a previously unstudied endorheic karstic system is presented. The studied area, known as the Esta?a Lakes, is located in the Pyrenean Marginal Sierras, northern Spain. The Esta?a Lakes are a set of natural water ponds on a bedrock of Triassic evaporites, lutites and carbonates. This wetland is included in the Natura 2000 European network of nature protection areas as a “Site of Community Importance”. Two geophysical techniques were used, magnetic resonance sounding (MRS) and electrical resistivity tomography (ERT), to map the subsurface geology and characterize the aquifer layers and the hydraulic links between the aquifers and lakes. The geophysical data were integrated with the surface geology and data from six boreholes. Ten electrical profiles were performed to identify the thickness of the units and lithological changes, whereas the MRS was used to determine the top of the saturated zone. As result, the aquifer in the Esta?a Lakes system and surrounding area has been identified as Middle Triassic carbonates, which does not correspond with the regional aquifer in the area (Upper Cretaceous and Eocene). This work shows the power of geophysical methods in poorly understood and tectonically complex areas in addition to the standard aquifer tests to evaluate hydraulic properties.  相似文献   

9.
Knowledge of the existence of fracture zones, their extent, intensity and direction is very useful for assessing groundwater in hardrock regions and in this context geophysical methods are widely accepted as a powerful means of study. In the modern era of exploration, application of the Resistivity Imaging technique gives a new opportunity for groundwater study in hardrock regions. Exploration surveys were conducted at one of the important sites in Maheshwaram watershed, Andhra Pradesh, India with a multielectrode resistivity imaging system. To reduce the ambiguity of geophysical interpretation some complementary geophysical studies like ground Magnetic and VLF were also carried out.A number of 2D resistivity images were prepared in a grid pattern, which clearly show the weathered and fractured zones in different parts of the study area. With the help of all 2D profiles a quasi-3D image has been created, which indicates the orientation and extension of the fracture zone in a horizontal as well as vertical direction in the study area. Strong agreement exists among the anomalies identified using the ground magnetic, VLF and resistivity imaging methods. The litholog data available in the study area also helps to interpret geophysical results to find a potential groundwater bearing zone in that area.  相似文献   

10.
Bhadra  B. K.  Gor  Naresh  Jain  Ashish K.  Meena  Hansraj  Rao  S. Srinivasa 《Hydrogeology Journal》2021,29(8):2705-2724

The Great Rann of Kachchh (GRK) in Gujarat, India, is the largest salt desert in the world, which is usually filled with seawater ingression during high tide from the Arabian Sea. As a result, the soil gets saturated with saline water that has percolated down for several meters. Groundwater exploration in Rann area is a challenging task due to the prevailing hostile environment. For this purpose, multisensor satellite data have been used to delineate the palaeochannels in search of an alternate source of drinking water. In GRK, palaeochannels represent the zone of elevated fluvial sediments with respect to the surroundings. Evolutionary history of the palaeochannels indicates upliftment of GRK area during Allah Bund faulting. For assessing the groundwater potential of the palaeochannels, high-resolution electrical resistivity tomography (HERT) surveys have been carried out with the pole-dipole method. Electrical resistivity tomograms along 710 m traverses to a depth of 250 m in Dharmsala and Gainda area show higher-resistivity zones (medium to coarse sand with brackish water) below a thick low-resistivity layer (clay with saline water). A few exploratory drillings in the area confirm the existence of the palaeochannels, which act as a confined aquifer below 100 m depth. The artesian condition of the two drilled wells at Gainda and Khardoi along the northern boundary of GRK may be attributed to hydraulic gradient along the confined layers from the Tharparkar region in Pakistan. Thus, HERT is found to be a faster and more cost-effective geophysical survey technique for study of the deep aquifer.

  相似文献   

11.
Geoelectrical resistivity techniques are increasingly being applied in addressing a wide range of hydrological, environmental, and geotechnical problems. This is due to their effectiveness in near-surface characterization. In the present study, a suite of vertical electrical soundings (VESs) was integrated with 2D geoelectrical resistivity and time-domain induced polarization (IP) imaging to characterize the near-surface and delineate the underlying aquifer in a sedimentary terrain. The geophysical survey was conducted as part of preliminary studies to evaluate the potential of groundwater resource in Iyana-Iyesi and Canaan Land area of Ota, southwestern Nigeria. A high-yield confined sandy aquifer overlain by a low-yield aquitard was delineated; overlying the aquitard is a very resistive and thick layer that is predominantly composed of kaolinitic swelling clay intercalated with phosphate mineral.  相似文献   

12.
Two geophysical techniques were integrated to map the groundwater aquifers on complex geological settings, in the crystalline basement terrain in northeast Nuba Mountains. The water flow is structurally controlled by the northwest–southeast extensional faults as one of several in-situ deformational patterns that are attributed to the collision of the Pan-African oceanic assemblage of the Nubian shield against the pre-Pan African continental crust to the west. The structural lineaments and drainage systems have been enhanced by the remote sensing technique. The geophysical techniques used are: vertical electrical soundings (VES) and electrical resistivity tomography (ERT), in addition to hydraulic conductivity measurements. These measurements were designed to overlap in order to improve the producibility of the geophysical data and to provide a better interpretation of the hydrogeological setting of the aquifer complex structure. Smooth and Block inversion schemes were attempted for the observed ERT data to study their reliability in mapping the different geometries in the complex subsurface. The VES data was conducted where ERT survey was not accessible, and inverted smoothly and merged with the ERT in the 3D resistivity grid. The hydraulic conductivity was measured for 42 water samples collected from the distributed dug wells in the study area; where extremely high saline zones were recorded and have been compared to the resistivity values in the 3D model.  相似文献   

13.
孙浩  刘营  王正  王振  刘荆平  陈超  王国灿  王岸 《地球科学》2022,47(11):4280-4293
覆盖区地质填图是新时期地质填图的重要方向.音频大地电磁法(AMT)是覆盖区地质填图的重要地球物理方法之一,可以为地层和基岩面的刻画提供电性参数的约束.然而,常规的AMT反演无法精确刻画电性异常体的边界,且当缺乏其他地质与地球物理资料约束时,难以进行地质解译.针对此问题,基于数值模拟结果的可行性,利用哈密烟墩戈壁覆盖区的4条实测AMT剖面探讨了AMT约束反演在地层识别中的应用效果.相位张量分析指示研究区浅部(> 1 Hz)电性结构表现为二维特征,深部受三维结构影响;浅部为低阻,深部电阻率逐渐升高.采用不加约束二维反演获得了4条剖面的地下(< 3 km)电性结构.基于研究区的重力异常、地震解译结果、物性和钻孔资料,在二维反演结果上初步划分了渐新统-中新统和侏罗系地层的底界面;进而以这两个界面建立先验模型,并根据物性资料设置电阻率变化范围,进行AMT约束反演,获得了更优化的反演结果以及清晰可靠的渐新统-中新统和侏罗系的底界面.结果显示,研究区渐新统-中新统地层电阻率值略小于10 Ω?m,其底界面平均埋深为120 m;侏罗系电阻率值为10~100Ω?m,其底界面最深可达2 km.基岩面(侏罗系底界面)埋深整体上呈现为东南深、西北浅,这指示哈密烟墩地区中生代以来的沉积中心在东南部;此外,侏罗系地层与下伏的古生界地层存在角度不整合.研究表明,哈密烟墩地区新生代以来可能受到了近南北向应力挤压,在研究区中部形成近东西或北东东向的侏罗系隆凹相间的构造地貌格局.而渐新统-中新统地层底部的不整合面可能反映了后期褶皱构造的影响,这种隆凹作用相伴的褶皱构造可能具有同沉积性质.   相似文献   

14.
This article compares the efficiency of induced polarization (IP) and resistivity in characterizing a contamination plume due to landfill leakage in a typical tropical environment. The resistivity survey revealed denser electrical current flow that induced lower resistivity values due to the high ionic content. The increased ionic concentration diminished the distance of the ionic charges close to the membrane, causing a decrease in the IP phenomena. In addition, the self-potential (SP) method was used to characterize the preferential flow direction of the area. The SP method proved to be effective at determining the flow direction; it is also fast and economical. In this study, the resistivity results were better correlated with the presence of contamination (lower resistivity) than the IP (lower chargeability) data.  相似文献   

15.
This paper is devoted to application of SP, resistivity and mise-a-la-masse method in Khenadarreh (Arak, Iran) graphite deposit exploration. Mise-a-la-masse method is one of the main geophysical exploration methods used to investigate conductive bodies with outcrops on the surface or in exploratory pits. By integrating mise-a-la-masse results with other geoelectrical methods, such as self-potential and resistivity surveys, useful results can be acquired. Powerful survey design, data processing and interpretation methods can make geoelectrical surveying results more reliable. Here, we applied integrated geoelectrical methods to explore the Khenadarreh-bala graphite deposit in the Sarband region of the Markazi province, Iran. We present a new and simple method for processing and interpreting mise-a-la-masse data, which corrects for the effect of distance from the current electrode in the conductive body. After correction, the residual potential values corresponded with the SP results and the apparent resistivity pseudosections. The geophysical results were confirmed by drill holes in the study area.  相似文献   

16.
A series of geophysical parameters have been applied with geological perception to resolve the hydrogeological complexities over granitic terrain at Hyderabad, India. Frequent failure of borehole drillings and the thrust conditions of community have prompted a noninvasive suitable tool, applied at small scale for pinpointing potential well site. Geophysical scanning, viz. electrical resistivity tomography (ERT), spontaneous potential (SP), and electrical gradient profiling (GP) were employed within the restricted space of housing complex to obtain the true characteristics of the subsurface lithology, where anomalies by the underground utility structures have been nullified. Results showed, in ERT, the low order of resistivity range 123 to 200?Ωm showing a plume like weathered zone underlain by sudden slip of massive granite (>217?Ωm) was of great interest to proceed further in the process. Here, the switchover in SP value from +18 mV to ?17 mV and GP from mean value 10 to 90 mV/m was recorded. The anomalies in SP and GP were precisely coincided with the ERT where upcoming of subsurface massive granite next to the inferred fracture was noted. Drilling core logs satisfies the geophysical signatures ensuring the inferred saturated fracture with the total yield 1,302 gal/h.  相似文献   

17.
Seawater intrusion is a major problem in urbanized coastal regions of India which is due to over exploitation of groundwater for various purposes. This study was carried out with the objective of assessing the zone of mixing between seawater and groundwater in the coastal aquifer in south of Chennai, Tamil Nadu, India using high resolution electrical resistivity tomography. High resolution electrical resistivity tomography was carried out in five profiles perpendicular to the sea using IRIS make SYSCAL Pro-96 system with 2.5 m or 5 m inter-electrode separation. The maximum length of the profile was 170 m which resulted in a depth of investigation of 28.7 m. The apparent resistivity measured in this area varies from 0.3 ohm-m to 30,000 ohm-m. The apparent resistivity of saturated zone decreases towards the sea, indicating the influence of seawater. This was also confirmed by measuring the electrical conductivity of groundwater, which gradually increases from 156 μS/cm to 3430 μS/cm towards the sea. Further, the concentration profiles of electrical conductivity, sodium, chloride and chloride / bicarbonate ratio are compared with the high resolution electrical resistivity tomography profile. The distance of influence of seawater is comparatively high in northern part than in southern part of the area. The high resolution electrical resistivity tomography was effectively used to determine the effect of seawater mixing with groundwater.  相似文献   

18.
The combined use of geophysical and soil gas composition exploration methods allows to rapidly obtain at relative low cost information that might be related to seismic activity conditions. In this study, we carried out geochemical soil gas sampling (222Rn, 220Rn and CO2), electrical resistivity tomography and seismic refraction profiles in two selected zones near the town of Amer in the Spanish Pyrenees, where the presence of recent fractures is evident in the field. Data analysis clearly reveals anomalous values for each gas at specific positions along the electrical imaging transects. Geomorphologic and hydrogeologic data and the integration of geophysical data and soil gas measurements indicate that: (1) endogene gases radon (222Rn) and carbon dioxide (CO2) are released from the meta-sedimentary basement rocks across the main fractured zones with higher permeability values, while lower Cenozoic detrital sedimentary formations act as an impervious boundary; (2) sites with highest radon concentrations (52?kBq?m?3) coincide with the zones in the Amer fault showing more recent geomorphic evidence of activity, and more specifically with those areas covered by thinner surficial formations; (3) the lowest 222Rn values (0.2?C0.4?kBq?m?3) were recorded just on the master active fault plane. This pattern could be explained by a dilution effect resulting from high rates of soil CO2 efflux (267?g?m?2?day?1); (4) soil thoron (220Rn) activity is maximum (143?kBq?m?3) in areas with high surficial fracturing; (5) groundwater pumping may cause important distortions in the natural flow dynamics and in the measured concentrations of gases. The agreement between the different data (geochemical, geophysical, and hydrogeological) and field observations (geology and geomorphology) leads us to propose a preliminary tectonic-gravitational model for the study area.  相似文献   

19.
Diffusion and adsorption (DA) potentials are frequently the sources of self-potential (SP) anomalies, but they do not arouse practical interest in contrast to anomalies of oxidation–reduction and filtration origins. DA anomalies are common and geophysicists sometimes mistakenly consider DA anomalies as examples of filtration anomalies. Identification of DA anomalies is based on correlation of SP and apparent resistivity values along the same profiles. During the student geophysical training workshop for students of the Moscow State University (Aleksandrovka village, Kaluga Region) we obtained profiles with SP and resistivity anomalies with good correlation between them. This makes it possible to consider such SP anomalies as a result of DA processes.  相似文献   

20.
The Nev?ehir Castle region located in the middle of Cappadocia with approximately cone shape is investigated for the existence of an underground city using the geophysical method of electrical resistivity tomography. Underground cities are commonly known to exist in Cappadocia. The current study has obtained important clues that there may be another one under the Nev?ehir Castle region. Several 2.5-D resistivity profiles totaling approximately 4 km in length surrounding the Nev?ehir Castle are measured to determine the distribution of electrical resistivities under the study area. Several high resistivity anomalies with a depth range 8–20 m are discovered to associate with a systematic void structure beneath the Nev?ehir Castle. Because of the high-resolution resistivity measurement system currently employed, we were able to isolate the void anomalies from the embedding structure. Using 3-D visualization techniques, we show the extension of the void structure under the measured profiles.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号