首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
A series of geophysical parameters have been applied with geological perception to resolve the hydrogeological complexities over granitic terrain at Hyderabad, India. Frequent failure of borehole drillings and the thrust conditions of community have prompted a noninvasive suitable tool, applied at small scale for pinpointing potential well site. Geophysical scanning, viz. electrical resistivity tomography (ERT), spontaneous potential (SP), and electrical gradient profiling (GP) were employed within the restricted space of housing complex to obtain the true characteristics of the subsurface lithology, where anomalies by the underground utility structures have been nullified. Results showed, in ERT, the low order of resistivity range 123 to 200?Ωm showing a plume like weathered zone underlain by sudden slip of massive granite (>217?Ωm) was of great interest to proceed further in the process. Here, the switchover in SP value from +18 mV to ?17 mV and GP from mean value 10 to 90 mV/m was recorded. The anomalies in SP and GP were precisely coincided with the ERT where upcoming of subsurface massive granite next to the inferred fracture was noted. Drilling core logs satisfies the geophysical signatures ensuring the inferred saturated fracture with the total yield 1,302 gal/h.  相似文献   

2.
Self potential (SP) and electrical resistivity tomography (ERT) methods are used together with the results of groundwater samples hydrogeochemical analysis to assess the impact of the water leak from the landfill garbage site at NamSon located in Northern Hanoi on causing pollution to the surrounding environment and affecting geological structure. Selected survey area covers an area of 180 × 300 m lying in the low land of the NamSon site with a slope ranging about 8 m in direction NW–SE. There are three geophysical measurements lines denoted as T1, T2 and T3. Processing 180 SP data points has allowed to draw maps of equipotential epoch in the two periods in 2015 and 2016. The maps show four zones of SP positive anomalies with maximum amplitudes of about +20 mV where the groundwater flow direction is downward and five zones of SP negative anomalies with minimum values in a range from ?180 to ?260 mV where the groundwater flow direction is upward. Resistivity values of the subsurface layers of soils and rocks have been aquired from 2D inverse model for measuring ERT in March 2015 and March 2016. The results of the ERT allowed to define the low resistivity in the range 15–20 Ωm related to leachate plume from NamSon landfill site. Results of the physico-chemical analysis of groundwater samples from the existing six boreholes show increases in concentration of the measured pollutant parameters indicating contamination of the groundwater as a result of solid waste leachate accumulation. This result is affirmative evidence for the survey results by geophysical technique. The rapid decrease in quality of groundwater over the last year is probably due to the influence of the leachate from the NamSon landfill site.  相似文献   

3.
As part of a larger regional research program “KarstEAU”, the authors have applied electrical resistivity tomography (ERT) techniques to characterize heterogeneities in the Port-Miou coastal karst aquifer (Cassis, SE France). Field surveys were carried out on intensely fractured and karstified Urgonian carbonates. Extensive research has characterized macro- and micro-scale geology of the Port-Miou area and particularly underground water-filled conduits and fault/fracture and karst systems within a former quarry. The authors applied 2D ERT along two surface profiles of length 420 and 595 m to test capability for delineating subsurface conduits and possibly relationship between conduit and fault/fracture/karst orientation; and 3D ERT with a dense 120 electrode array at 1 m spacing (11 × 10 m) was applied over an area of the quarry that had been profiled using 3D georadar and which has had intensive nearby structural geological interpretation. The 2D profiling imaged several underground conduits at depths to >50 m below ground surface and below sea level, including possibly the main Port Miou submarine spring and smaller springs. The 2D profiling within the quarry provided a better understanding of the connectivity between major fractures and faults on the quarry walls and secondary springs along the coast supporting flow of the secondary springs along interpreted fracture orientations. In addition, 2D inversion-derived conductivity models indicate that high resistivity zones above sea-level are associated with non-saturated zones and low resistivity anomalies in the non-saturated zone are associated with residual clays in paleokarsts. A partitioned lower resistivity zone below sea-level can be associated with a higher porosity/permeability zone with fractures and karstic features. Inversion models of the dense 3D ERT data indicate a higher resistivity volume within the larger surveyed block. The survey characterized the non-saturated zone and the ERT resistivities are correlated with karst features interpreted by 3D georadar and visible in the inferior wall of the quarry.  相似文献   

4.
陈伟军 《地质与勘探》2016,52(2):246-250
内蒙古老国营子金铜矿床是近年来利用地质与地球物理相互结合手段新发现的一个矿床。本次研究利用基于电磁原理的地球物理手段进行了找矿测试,结果表明:甚低频(VLF)地球物理扫面发现了近EW向和NW向的高阻带,分别对应了两条相应的矿化蚀变带。音频大地电磁法(EH4)测深影像显示矿化蚀变带表现为高阻异常带,与VLF的测量结果相一致。激电(IP)中梯测量显示矿化蚀变带具有高阻、高充电率和高金属因子异常特征。结合具体的地质特征,在老国营子金铜矿区综合运用这三种地球物理方法,取得了较好的找矿效果。  相似文献   

5.
Landslides are very common in high-altitude Himalayan terrains. Major roads in the Himalayas are frequently blocked due to heavy landslides and remain closed for long periods of time. Permanent mitigatory solutions to these landslides are required to keep the highways open. Lanta Khola, located 71.2 km north of Gangtok (capital of the Indian state of Sikkim), is one of the oldest landslides on the North Sikkim Highway and is active since 1975. The rock types on either side of the landslide are different (augen gneiss in the east and metapelitic schist in the west), and it is believed that the Main Central Thrust passes through the slide zone. Since the slide is invariably activated in the aftermath of heavy rainfall, it is important to identify the subsurface structures that channel water below the landslide surface in order to understand the triggers of slide activity. This can only be accomplished by geophysical survey; however, an appropriate geophysical technique that can be applied in such terrains must be identified. Very low-frequency (VLF) electromagnetic survey was performed over the Lanta Khola landside in order to delineate subsurface structures. Although a very limited number of VLF transmitters are available worldwide, it was possible to pick up VLF signals from a number of VLF stations even in this high-altitude mountainous terrain. VLF measurements along five profiles perpendicular to the geological strike were recorded, and a high conducting zone was delineated from the VLF observations. This conducting zone correlates with the low resistive zone identified from gradient resistivity profiling. The anomalies confirm that there is a water-saturated zone (soggy zone) even in the subsurface of the slide parallel to the geological gneiss–schist contact within the Lanta Khola slide. This indicates that the conductive feature correlates with a weak water-saturated debris layer that lies along the slide and is parallel to the geological contact. Resistive structures on either side of the landslide zone can thus be correlated with the stable ground. It is necessary to drain out water from the soggy zone to minimize slide activity since this zone appears to penetrate into the body of the slide.  相似文献   

6.
The Haveri tailings area contains 1.5 Mt of sulfide-bearing waste from the Au–Cu mine that operated during 1942–1961. Geophysical and geochemical methods were used to evaluate and characterize the generation of acid mine drainage (AMD). Correlations were examined among the electrical resistivity tomography (ERT) data, the total sulfide content and concentrations of sulfide-bound metals (Cu, Co, Fe, Mn, Ni, Pb and Zn) of tailings samples, and the resistivity and geochemistry of surface water. The resulting geophysical–geochemical model defines an area in the vadose tailings, where a low resistivity anomaly (<10 Ohm m) is correlated with the highest sulfide content, extensive sulfide oxidation and low pH (average 3.1). The physical and geochemical conditions, resulting from the oxidation of the sulfide minerals, suggest that the low resistivity anomaly is associated with acidic and metal-rich porewater (i.e., AMD). The lower resistivity values in the saturated zone of the central impoundment suggest the formation of a plume of AMD. The natural subsoil layer (silt and clay) and the bedrock surface below the tailings area were well mapped from the ERT data. The detected fracture zones of the bedrock that could work as leakage pathways for AMD were consistent with previous geological studies. The integrated methodology of the study offers a promising approach to fast and reliable monitoring of areas of potential AMD generation and its subsurface movement over large areas (ca. 9 ha). This methodology could be helpful in planning drill core sampling locations for geochemical and mineralogical analysis, groundwater sampling, and choosing and monitoring remedial programs.  相似文献   

7.
Integrated surface electrical resistivity and electromagnetic (EM) surveys were conducted in a hard-rock terrain of Southwestern Nigeria in the vicinity of active oxidation sewage treatment ponds. The aim was to detect soil contamination due to the spread of sewage effluent, locate possible leachate plumes and conductive lithologic layers, and access the risk of groundwater pollution in the vicinity of the sewage-ponds. Dipole–dipole resistivity profiling and very low frequency (VLF) data were acquired at 10-m intervals along five 200-m long east-west geophysical traverses. Resistivity sections obtained revealed four subsurface geologic layers comprised of lateritic clay, clayey sand/sand, weathered/fractured bedrock, and competent bedrock. A distinct low resistivity zone corresponding to the contamination plume (labeled B) was delineated from all the resistivity sections. This low zone extends into the weathered bedrock and possibly suggests contamination of this layer. The filtered real component of the processed VLF data detected three distinct anomaly zones that are representative of fractured zones filled with conductive fluids and/or lithologic boundaries that possibly serve as conduits for the movement of contaminated effluents. The results obtained from the two methods suggest possible contamination of the subsurface soil layers and groundwater in the vicinity of the sewage-ponds. The existence of this contaminated plume poses a serious threat to the ecosystem and health of the people living in the vicinity of the sewage-ponds.  相似文献   

8.
Three years after the oil spillage and pipeline explosion that claimed about 100 human lives at Ijegun Community of Lagos–Nigeria, a combination of carefully designed 2D Electrical Resistivity Profilling and Vertical Electrical Sounding methods was deployed to map and characterise the subsurface around the contaminated site. Data acquired were processed, forward modelled and tomographically inverted to obtain the multi-dimensional resistivity distribution of subsurface. The results of the study revealed high resistivity structures that indocate the presence of contaminant (oil plumes) of different sizes and shapes around the oil leakage site. These high resistivity structures are absent in the tomograms and resistivity-depth slices computed for Iyana—a linear settlement not affected by oil spillage. The five geo-electric layers and the resistivities delineated in the area are the top soil layer, 220–670 Ωm; clayey sand layer, 300–1072 Ωm; top sand layer, 120–328 Ωm; mudstone/shale layer, 25–116 Ωm and the bottom sand layer, 15–69 Ωm. The base of the first four geo-electric layers corresponds to 3.9, 8.4, 27.2 and 34.6 m respectively. The two groundwater aquifers delineated correspond to the third and fifth geo-electric layers. The top aquifer has been infiltrated by oil plumes. The depth penetrated by the oil plume decreases from 32 m to about 24 m across the survey profiles from the two ends. It was concluded that the contaminant plumes from the oil spillage are yet to be completely degraded as at the time of the study. It is recommended that the contaminated site be remediated to remove or reduce the contaminant oil in the subsurface.  相似文献   

9.
This research is an attempt to accomplish a 3-D resistivity imaging survey, which was carried out near a water well contaminated with hydrocarbon materials in Karbala governorate. Two-dimensional resistivity imaging measurements were collected along four parallel profiles, using a Wenner array with electrode spacing of 1 m. The RES3DINV program was used to invert the apparent resistivity data. The results displayed a resistivity distribution of the subsurface in a three-dimensional volume. Thus, both the horizontal and vertical extents of the contaminated zone were displayed. This technique revealed a low resistivity zone at depth ranges from 3 to 6 m in the investigation area, but the seepage starts at depth ranges between 2 and 3 m and continues down depth (may be to the groundwater level). This low resistivity zone is the most likely location for a subsurface seepage of contaminated water. It is clear that the sufficient measurement points along 2-D lines in a small area can increase the 3-D imaging resolution, and nearly real 3-D imaging can be achieved, when the size of subsurface anomaly compared with the electrode spacing (a) of the Wenner array is taken into consideration.  相似文献   

10.
Surface geophysical methods were used to determine the locations of fracture zones in part of the hard rock area in Sonebhadra District of Uttar Pradesh, India. The survey comprises three DC resistivity profile using the gradient profiling technique and ten very low frequency electromagnetic (VLF-EM) traverses profiles. The methods were used over survey lines extending between 200 and 400 m; the results were correlated to locate fracture zones for the purpose of groundwater exploration. Qualitative interpretation of the VLF-EM was carried out using Fraser and Karous–Hjelt filters. The result of the interpretation revealed a number of subsurface zones with high real component current density that defines the potential subsurface features (probably fracture zones). The subsurface feature concurred with the low resistive zones indentified from the gradient resistivity profiling. The zones where further inferred quantitatively using data obtained from DC resistivity sounding at some selected anomalous points. The result obtained proves the efficiency of integrating both methods in detecting fractures zones in hard rock area.  相似文献   

11.
内蒙古西乌珠穆沁旗布敦乌拉矿区多为第四系覆盖。在该矿区多金属勘查中,依据土壤地球化学圈定的矿化异常布置激电中梯测量,圈定1处激发极化率异常区,长度约890m,宽度约520m,位于已知断层F 1与推断断层F 2之间。采用可控源音频大地电磁测深剖面对该激电异常进行探测,解释视充电率多峰异常与反演电阻率高低跳跃对应区域为矿致异常区。通过钻探验证,发现银多金属矿床资源储量523.93万t,取得了良好的地质找矿效果。  相似文献   

12.
A novel study on using geoelectrical resistivity, soil property, and hydrogeochemical analysis methods for delineating and mapping of heavy metal in aquifer system is presented in this paper. A total of 47 surveys of geoelectrical resistivity with Wenner configuration were conducted to determine the subsurface and the groundwater characteristics. The groundwater sample from 53 existing wells and 2 new wells has been analyzed to derive their water chemical content. The chemical analysis was done on the soil sample obtained from new two wells and from selected locations. The water and soil chemical analysis results from the new two wells were used as calibration in resistivity interpretation. The occurrence of heavy metal in aquifer system was expected to detect using the geoelectrical resistivity survey for the whole study area. The result of groundwater analysis shows that the groundwater sample contains a relatively low concentration of Fe (<?0.3 mg/L) elongating from the south up to the middle region. While in the middle and the northwestern, Fe concentration is relatively high (around 12 mg/L). Chemical analysis of soil sample shows that in the lower resistivity zone (<?18 Ωm), Al and Fe concentrations are comparatively high with an average of 68,000 and 40,000 mg/kg, respectively. Starting from the middle to the northwestern zone, the resistivity value appears to be low. It is definitely caused by higher Al and Fe concentration within the soil, and it is supported also by lower total anion content in the groundwater. While the resistivity value of more than 40 Ωm in aquifers is obtained in the zone which Fe concentration is relatively lower in the soil but not present in the groundwater. Correlation Fe concentration in the soil and Fe concentration in the groundwater sample shows the trend of positively linear; however, the Al concentration in soil has no correlation with Al content in groundwater. Finally, the probability of high heavy metal zone in the aquifer system is easily delineated by the distribution of geoelectrical resistivity presented in depth slice shapes which extend from the Boundary Range Composite Batholith in the north to the northwest.  相似文献   

13.
Near-surface geophysical methods are commonly used to solve a wide class of geological, engineering and environmental problems. In this study, a geoelectrical survey was performed to investigate an alluvial aquifer. The study area is located in the southwest of the Çubukluda? graben, situated in the south of ?zmir, Turkey. The geophysical studies included the electrical resistivity imaging and self-potential (SP) methods. The resistivity data were acquired along eight profiles in the northern part of the study area by a Wenner-Schlumberger electrode configuration and the data processing was achieved by a tomographic inversion technique. The SP data were collected by gradient technique along 16 profiles. Total field values were calculated for each profile by addition of the successive gradient values, then a total field SP map was obtained. The water-saturated zone in the northern part of the study area was clearly revealed by the electrical resistivity imaging and the SP survey yielded useful information on the subsurface fluid movement.  相似文献   

14.
双频激电法可同时得到低频和高频电位差,由其计算视幅频率可抵消相同的影响因素,抑制干扰,增强异常幅值,提高观测精度。根据垄源金多金属矿区物性参数可确定受构造控制的硫化多金属矿(脉)体多以充填形式产出,具有低阻高极化反映,随着埋深的不同,视幅频率(Fs)有相应的变化,幅值一般为4%~11%,与背景视幅频率(Fs)2%~4%有明显差别。该区野外工作采用SQ-3C双频激电仪器,测网布设测线6条,其中线距100m、点距10m、、测线长度为400m。根据Fs、ρs曲线形态及Fs等值线图解释该矿区存在一条破碎带,破碎带北部呈现矿体异常特征,推断矿体(脉)走向为北西—南东向。依据该物探成果结合地质资料,布置钻探验证孔,其中8-1孔于156m见导水断裂破碎断层,8-2孔于31m见高品位金多金属矿(脉)体,验证物探解释与地质钻探吻合。  相似文献   

15.
This work presents the application of the ground-penetrating radar (GPR) method and electric resistivity tomography (ERT) technique in outlining a zone of contamination due to the light non-aqueous phase liquid (LNAPL) plume underground in the area of an impacted fuel station, close to Abha City. The GPR has been performed using SIR3000 unit with the 100 and 400 MHz antennas. The main objective of the GPR survey was to evaluate the lateral extension of contamination. The complex GPR signature of the plume was well characterized. Low reflectivity zone corresponds to hydrocarbon vapor phase in the vadose zone. Enhanced reflections are associated with free and residual products in the fractured saturated zone directly above the water table. An electric resistivity tomography (ERT) survey was performed on four profiles within the site to investigate the vertical and horizontal extent of the contamination plume and to define the bottom of the landfill. The 2D electric profiles show the presence of low-resistivity (4O to 37 Ω m) anomalies that refers to the presence of accumulated hydrocarbons. From the interpretation of the GPR and ERT profile, it was possible to locate the top and bottom of the contamination plume of the waste disposal site. The radar signal penetrated deep enough and enabled the identification of a second reflector at approximately 10-m deep, interpreted as the hard basement surface which causes the strong amplitude reflection in the GPR profile. The results of GPR and ERT showed good agreement.  相似文献   

16.
The use of resistivity sounding and two-dimensional (2-D) resistivity imaging was investigated with the aim of delineating and estimating the groundwater potential in Keffi area. Rock types identified are mainly gneisses and granites. Twenty-five resistivity soundings employing the Schlumberger electrode array were conducted across the area. Resistivity sounding data obtained were interpreted using partial curve matching approach and 1-D inversion algorithm, RESIST version 1.0. The 2-D resistivity imaging was also carried out along two traverses using dipole–dipole array, and the data obtained were subjected to finite element method modeling using DIPRO inversion algorithm to produce a two-dimensional subsurface geological model. Interpretation of results showed three to four geoelectrical layers. Layer thickness values were generally less than 2 m for collapsed zone, and ranged from 5 to 30 m for weathered bedrock (saprolite). Two major aquifer units, namely weathered bedrock (saprolite) aquifer and fractured bedrock (saprock) aquifer, have been delineated with the latter usually occurring beneath the former in most areas. Aquifer potentials in the area were estimated using simple schemes that involved the use of three geoelectrical parameters, namely: depth to fresh bedrock, weathered bedrock (saprolite) resistivity and fractured bedrock (saprock) resistivity. The assessment delineated the area into prospective high, medium and low groundwater potential zones.  相似文献   

17.
阿希金矿脉由里向外具有含金石英脉→硅化带→黄铁绢英岩化的产出特征,其矿区物性测定结果显示,黄铁绢英岩化带电阻率变化范围为60~400Ω·m,其他未蚀变的岩石呈现较高电阻率值,具备了电法勘探的前提条件,即探测富含黄铁矿的黄铁绢英岩化带的分布范围,便可达到寻找金矿矿体目的。本次勘探运用不同电法勘探的特点,通过高密度电法了解浅部矿化信息与矿体平面定位,再利用Stratagem EH4电导率成像及加拿大凤凰公司研制的V系列综合电法进行浅部对比和深部解译,并对其不同方法进行了验证。从勘查区11号线相互佐证的成果图上看,在该勘探线北测深部约400m处,存在一倾角较大的低阻异常,后经钻孔验证,在360m深度见到含金蚀变英安岩及含金石英脉矿体。  相似文献   

18.
Geological transition zones are noted to be problematic in groundwater potential and development, due to their erratic and complex nature as well as characteristic of the subsurface lithologies. There were several occurrences of reported borehole failures and dry wells in these zones in Nigeria as a result of very scanty information that could serve as database for studying its groundwater potential. This study was therefore designed to generate hydrogeophysical data that could serve as baseline information on the groundwater potential in the study. In addition, to also delineate various subsurface lithologies present. Electrical resistivity survey for geophysical investigation was carried out using vertical electrical sounding (VES) technique. A total of 150 VES stations were purposively probed using Schlumberger electrode array. The interpreted data were used to produce geoelectric subsurface lithologies and to draw the geological section across the entire area. Various subsurface lithologies with their resistivities (Ωm) were delineated for basement complex (BC), transition zone (TZ), and sedimentary terrain (ST). In BC were topsoil, weathered zone, and fresh bedrock and in TZ were topsoil, sandy, laterite/clay, dry sand, sandstone, and fresh bedrock delineated while in the ST, topsoil, lateritic and sandy clay, dry sand, and the sandstone were delineated. In conclusion, the groundwater potential of the study area is largely been affected by the topography and the nature/composition of the Abeokuta Group that underlie the sedimentary part of the study area and the presence of thick laterite/clay unit of the basement complex portion of the study area.  相似文献   

19.
Recently, the deterioration of water quality in the coastal zones of Lekki Peninsula area of Lagos due to saltwater infiltration into the freshwater aquifer has become a major concern. With the aim of providing valuable information on the hydrogeologic system of the aquifers, the subsurface lithology and delineating the groundwater salinity, vertical electrical resistivity (VES) sounding survey was carried out utilizing surface Schlumberger electrode arrays, and electrode spacing varying between 1 and 150 m. The DC resistivity surveys revealed significant variations in subsurface resistivity. Also, the VES resistivity curves showed a dominant trend of decreasing resistivity with depth (thus increasing salinity). In general, the presence of four distinct resistivity zones were delineated viz.: the unconsolidated dry sand (A) having resistivity values ranging between 125 and 1,028 Ωm represent the first layer; the fresh water-saturated soil (zone B) having resistivity values which correspond to 32–256 Ωm is the second layer; the third layer (zone C) is interpreted as the mixing (transition) zone of fresh with brackish groundwater. The resistivity of this layer ranges from 4 to 32 Ωm; while layer four (zone D) is characterized with resistivities values generally below 4 Ωm reflecting an aquifer possibly containing brine. The rock matrix, salinity and water saturation are the major factors controlling the resistivity of the formation. Moreover, this investigation shows that saline water intrusion into the aquifers can be accurately mapped using surface DC resistivity method.  相似文献   

20.
The aim of this work is the joint application and integration of non-invasive geoelectrical methods for studying the landfill of Savoia di Lucania (Southern Italy). This landfill for its engineering features and small dimensions (70 m × 30 m × 6 m) represents an optimal test site to assess a geophysical survey protocol for municipal solid waste landfills investigation and monitoring. The landfill of Savoia di Lucania has been built with a reinforced concrete material and coated with a high-density polyethylene (HDPE) liner. Three electrical resistivity tomographies (ERT), two self-potential (SP) map surveys and one induced polarization (IP) section have been performed, both in the surrounding area and inside the waste landfill. The geophysical investigations have well defined some buried boundaries of the landfill basin and localized the leachate accumulation zones inside the dumpsite. Comparison of our results with other engineering and geological investigations could be the key for evaluating the integrity of the HDPE liner. Finally, the joint use of the ERT, IP and SP methods seems to be a promising tool for studying and designing new monitoring systems able to perform a time-lapse analysis of waste landfill geometry and integrity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号