首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The wastewater discharged by poultry slaughterhouse industries are characterized mainly by high biochemical oxygen demand, high suspended solids and complex mixture of fats, proteins and fibers requiring systematic treatment prior to disposal. In this study, the performance of an upflow anaerobic filter reactor for treating Indian poultry slaughterhouse wastewater under low upflow velocity of 1.38 m/day at mesophilic temperature (29-35 °C) was investigated. The reactor was inoculated with anaerobic non-granular sludge from an anaerobic reactor treating the poultry slaughterhouse wastewater. The reactor took 147 days for complete start-up with removal efficiencies of total chemical oxygen demand and soluble chemical oxygen demand of 70 and 79 % respectively. The maximum total chemical oxygen demand removal efficiency of 78 % was achieved at an organic loading rate of 10.05 kg/m3/day and at an hydraulic retention time of 12 h. The average methane content varied between 46 and 56 % and methane yield at maximum removal efficiency was 0.24 m3 CH4/kg CODremoved·day. Sludge granules of 1–2 mm were observed in between the packing media. Scanning electron microscope analysis revealed that sludge granules are composed of clumps of Methanosarcina clustered with less intertwined Methanosaeta fibre of granules. The lower velocity used in this study has achieved better performance of the reactor by creating active microbial formation with stable pH upto an organic loading rate of 14.3 kg/m3/day. This has proved that the poultry slaughterhouse wastewater can be treated using anaerobic filter reactor under low upflow velocity.  相似文献   

2.
Sago industry is one of the major small-scale sectors in India and over 800 units are located in the southern State of Tamilnadu. Processing of sago generates enormous quantities of high strength wastewater requiring systematic treatment prior to disposal. The present study is an attempt to treat the sago wastewater using Hybrid Upflow Anaerobic Sludge Blanket (HUASB) reactor, which offers the advantages of both fixed film and up flow anaerobic sludge blanket treatment. HUASB reactor with a volume of 5.6 L was operated at Organic Loading Rates varying from 10.7 to 24.7 kg COD/m3.day. After 130 days of startup, the reactor produced appreciable decrease in COD of wastewater and removed solids efficiently. The COD removal varied from 91–87%. While the removal of Total Solids was in the range of 61–57%, that of volatile solids varied from 70–67%. The ideal OLR for the reactor was 23.5 kg COD/m3.day. The findings of the study open up newer possibilities of design low cost and compact onsite treatment systems with very short retention periods.  相似文献   

3.
Modeling and simulation using GPS-X software for a packed bed up-flow anaerobic sludge blanket followed by a biological aerated filter were studied. Both treatment units were packed with a non-woven polyester fabric as a bio-bed. The system was operated at a hydraulic and organic loading rate of 9.65 m3/m2/d and 2.64 kg BOD5/m3/day. Verification of the experimental results and calibration of the model were carried out prior simulation and modeling. Variables under consideration were HLR, OLR, and surface area of the packing material. HLR and OLR are increased incrementally until the break through point has been achieved. The results obtained from modeling indicated that the treatment system has great potential to be used as an ideal and efficient option for high hydraulic and organic loading rates up to 19.29 m3/m2/d and 4.48 kg BOD5/m3/day. The model indicated that increasing the input HLR and OLR loads to the treatment system up to 50 % of the original values achieved removal efficiencies 98 % for TSS, 88 % for BOD5, and 85 % for COD. Moreover, increasing the HLR to four times the original value (38.59 m3/m2/d) reduced the efficiency of the treatment system to 50 % for COD and BOD5. However, the removal rates of TSS, TKN, and TP were not affected. Also, the modeling results indicated that increasing the surface area of the packing material increased the overall efficiency of the treatment system.  相似文献   

4.
Nowadays, natural resources are under increasing stress which fosters wastewater reuse planning and emphasizes on the decentralized wastewater treatment. Vermifiltration has been described as a viable alternative to treat domestic and urban wastewater, but few studies have focused on the impact of different filter packings on vermifiltration performance. This study evaluates the effect of vermicompost and sawdust in a single-stage vermifilter (VF) for urban wastewater treatment. After an acclimation period of 45 days, urban wastewater from a combined sewage collection system was applied continuously for 24 h. Earthworm stock density was of 20 g L?1, HRT of 6 h, HLR of 0.89 m3 m?2 day?1 and OLR of 7.38 g BOD5 day?1. System performance was assessed by the removal efficiencies of BOD5, COD, TSS, NH4 +, TN and TP, and fecal coliforms and helminth eggs elimination. Vermicompost (VE) and sawdust (SE) were tested, using an earthworm abundance of 20 g L?1. Treatment efficiencies were 91.3% for BOD5, 87.6% for COD, 98.4% for TSS and 76.5% for NH4 + in VE, and 90.5% for BOD5, 79.7% for COD, 98.4% for TSS and 63.4% for NH4 + in SE. Earthworms contributed to reduce NH4 + and TN removal and to increase NO3 ? concentration. No treatment was able to eliminate fecal coliforms down to guidelines values for wastewater irrigation as helminth eggs were completely eliminated. Single-stage vermifiltration system using both filter packings is inconsistent and cannot meet EU guideline values for discharge in sensitive water bodies and WHO guidelines for irrigation with treated wastewater.  相似文献   

5.
In this study, the characteristics of sewage of small community were determined for 6 months to ascertain the type of treatment required in subtropical conditions. The results demarcated sewage of this community as a medium-strength wastewater (chemical oxygen demand: 475 mg/L, biochemical oxygen demand: 240 mg/L and total suspended solids: 434 mg/L). Chemical oxygen demand to sulphate ratio of the sewage (11.6) established that it was amenable to anaerobic digestion. The temperature, strength, biodegradability and components of sewage were suitable for anaerobic digestion, and thus, upflow anaerobic sludge blanket reactor (UASB) was selected for its treatment. These reactors are often shutdown in small communities due to environmental and/or socio-economic factors. The ability of two UASB reactors, seeded with cow dung (UASBCD) and activated sludge of a dairy treatment plant (UASBASDIT) to restart after a long idle period of 12 months, was investigated along with sludge analysis by scanning electron microscope. Biomass in both reactors reactivated rapidly after shutdown period and within 30 days after substrate feeding achieved uniform removal efficiencies for chemical oxygen demand, total suspended solids, total dissolved solids, chloride and oil and grease. Chemical oxygen demand removal efficiency of both reactors became uniform and remained close to 80% after 30 days through reactivation of microbes in sludge bed due to adequate food and temperature conditions. During restart-up, at an average organic loading rate of 0.902 kg COD/m3 per day, methane yields of 0.091 and 0.084 m3/kg COD removed were achieved for UASBCD and UASBASDIT reactors, respectively.  相似文献   

6.
在多级折流板反应器生物处理装置中,采用活性炭为载体人工固定化生物处理合成染料废水,出水水质稳定, 出水中的烷烃肽链变短;其对CODCr和BOD5的去除率可达96.46%、99.77% ;对SO2-4和钙镁总量的去除效率超过80.37%、78.66%;折流板反应器的容积负荷率Nv可达2.8 kg COD/(d•m3)。活性炭经生物固定化后,不仅不会影响它的处理效果,还会延长活性炭的使用寿命;当冲击性有机负荷发生时,固定化生物活性炭能够承受并能很快恢复。  相似文献   

7.
A new constructed wetland was built to purify one polluted river in Taiwan, and this study was conducted to evaluate the treatment efficiency of the wetland. Due to the very limitation of available budget, several water quality items, which were stipulated by Taiwan’s Environmental Protection Administration for rivers, in the influent and effluent of wetland were analyzed and evaluated. These items included water temperature, pH, DO, BOD5, TSS, and NH4 +-N. The results showed that the average removal rates of total (unfiltered) BOD5, TSS and NH4 +-N were 36.9 %, 71.8 % and 47.1%, respectively. With the HRT more than 3.4 days, the wetland could treat the polluted river water effectively. Longer HRT in this wetland appeared no obvious improvement on the removal rate of TSS or NH4 +-N. However, BOD removal rate increased while the HRT (Hydraulic Retention Time) increased to about 5 days. In this wetland, the calculated mean first-order reaction rate constant (kT) for BOD5 was 0.15/day with a standard deviation of 0.13/day and for NH4 +-N was 0.24/ day with a standard deviation of 0.18/day. It is also concluded that there is a linear proportional relationship between BOD concentrations in the effluent of wetland and its influent mass loading rates, with the coefficient of determination (R2) of 0.6511. Similar result was seen for NH4 +-N as well, with the coefficient of determination (R2) of 0.5965. TSS removal rate was found to be linearly proportional to its influent mass loading rate, with the coefficient of determination (R2) of 0.4875.  相似文献   

8.
In this study, the performance of moving-bed biofilm sequencing batch reactor in operating the anaerobic/anoxic/oxic (A2O) process for treatment of wastewaters containing nitrogen and phosphorous was evaluated. For this purpose, a pilot system with two bench-scale sequencing batch reactors with a total volume of 30 L and functional volume of 10 L was used. The installation was elaborated using plexiglass, in which 60% of the functional volume consisted of PVC suspended carriers (Kaldnes K3) with a specific surface area of 560 m2/m3. The independent variables used in this study were hydraulic retention time (HRT) (1.5, 2, 2.5, 3, and 3.5 h) and the initial organic load (300, 500, 800, 1000 mg O2/L). The results showed impressive performance in the case of an initial organic load of 300 mg O2/L and HRT of 3 h with maximum removal of COD and TN, respectively, by 95.1 and 89.8%. In the case of an initial organic load of 1000 mg O2/L and HRT of 3.5 h, the maximum total phosphorus removal was 72.3%. Therefore, according to the analysis of data obtained by different HRTs, it was revealed that the system of A2O has greater efficiency in removing organic matter from wastewater in the shortest possible time.  相似文献   

9.
Laboratory scale studies were conducted in an up-flow anoxic bioreactor using synthetic fertilizer wastewater for ascertaining the denitrification efficiency. The performance of the reactor was compared using ethanol and topioca starch as the carbon source. The initial No3-N concentrations (50–250 mg/L) and hydraulic retention time (FTRT, 12–24 h) were varied to evaluate the COD and No3-N removal. The results from this study shows that ethanol gave very good denitrification efficiency (78–98%) compared to topioca starch (68–96%).  相似文献   

10.
This review carries out a comparative study of advanced technologies to design, upgrade and rehabilitate wastewater treatment plants. The study analyzed the relevant researches in the last years about the moving bed biofilm reactor process with only attached biomass and with hybrid biomass, which combined attached and suspended growth; both could be coupled with a secondary settling tank or microfiltration/ultrafiltration membrane as a separation system. The physical process of membrane separation improved the organic matter and NH4 +-N removal efficiencies compared with the settling tank. In particular, the pure moving bed biofilm reactor–membrane bioreactor showed average chemical oxygen demand, biochemical oxygen demand on the fifth day and total nitrogen removal efficiencies of 88.32, 90.84 and 60.17%, respectively, and the hybrid moving bed biofilm reactor–membrane bioreactor had mean chemical oxygen demand, biochemical oxygen demand on the fifth day and total nitrogen reduction percentages of 91.18, 97.34 and 68.71%, respectively. Moreover, the hybrid moving bed biofilm reactor–membrane bioreactor showed the best efficiency regarding organic matter removal for low hydraulic retention times, so this system would enable the rehabilitation of activated sludge plants and membrane bioreactors that did not comply with legislation regarding organic matter removal. As the pure moving bed biofilm reactor–membrane bioreactor performed better than the hybrid moving bed biofilm reactor–membrane bioreactor concerning the total nitrogen removal under low hydraulic retention times, this system could be used to adapt wastewater treatment plants whose effluent was flowed into sensitive zones where total nitrogen concentration was restricted. This technology has been reliably used to upgrade overloaded existing conventional activated sludge plants, to treat wastewater coming from textile, petrochemical, pharmaceutical, paper mill or hospital effluents, to treat wastewater containing recalcitrant compounds efficiently, and to treat wastewater with high salinity and/or low and high temperatures.  相似文献   

11.
This paper presents the findings of the study on treatment of domestic wastewater using a laboratory scale Hybrid Upflow Anaerobic Sludge Blanket (HUASB) reactor. The reactor with a working volume of 5.9 L and plastic cut rings as packing media was operated at varying Hydraulic Retention Time (HRT) for a period of 110 days. While the COD removal varied from 75–86%, the BOD removal was in the range of 70–91%. Methane content in the biogas was 62±3%. VFA levels fluctuating between 100 and 186 mg/L (as acetate) did not pose operational problems such as souring of the reactor. During the treatment, nutrient levels exhibited an increasing trend. HUASB system could be designed with very short HRT of 3.3 hours, which will reduce the treatment cost significantly. It appears to be a promising alternative for the treatment of domestic wastewater in developing countries like India  相似文献   

12.
A sandwich domestic wastewater-fed dual-chamber microbial fuel cell (MFC) was designed for energy generation and wastewater treatment. The generated power density by the MFC was observed to increase with increasing chemical oxygen demand (COD) of the domestic wastewater. The maximum power density was 251 mW m?2 when the COD was 3400 mg L?1 at a current density of 0.054 mA cm?2 and external resistance of 200 Ω. These values dropped to 60 mW m?2 (76 % lower) and 0.003 mA cm?2 using wastewater 91 % diluted to 300 mg L?1 COD. Maximum removals were: COD, 89 %; nitrite, 60 %; nitrate, 77 %; total nitrogen, 36 %; and phosphate, 26 %. Coulombic efficiency ranged from 5 to 7 %. The use of full-strength domestic wastewater reduces cost, and with improved reactor design, the ultimate goal of large-scale operation could be achieved.  相似文献   

13.
在上流式好氧颗粒污泥床反应器中, 以厌氧颗粒污泥和好氧絮状活性污泥为接种泥, 采用人工配制的模拟废水, 成功培养出性能优异的好氧颗粒污泥.反应器内污泥浓度稳定在5g/L左右, 颗粒污泥粒径为0.5~2.0mm, 当进水COD为2000mg/L, 容积负荷为4.8kg/(m3·d)时, 系统对COD的去除率稳定在96%以上.通过扫描电镜观察, 好氧颗粒污泥是层状结构, 表面有大量丝状菌缠绕, 内部有短杆菌和空穴存在.逐步提高制药废水在进水中的比例, 经过47d的培养, 生物制药废水完全取代模拟废水, 系统对COD、NH3-N、TP的去除率分别稳定在90%、90%和70%以上.   相似文献   

14.
A combined ABR–MBR process consisting of an anaerobic baffled reactor (ABR) combined with an aerobic membrane bioreactor (MBR) treating municipal wastewater was investigated at controlled pH range 6.5–8.5 and at constant temperature 25 ± 1 °C. Total nitrogen (TN), ammonia (NH4 +–N), total phosphorus (TP), and chemical oxygen demand (COD) removal performances were evaluated by analyzing the mechanism for efficient nutrient removal. The results showed that the average removal rates of COD, NH4 +–N, TN, and TP reached 93, 99, 79, and 92 %, respectively, corresponding with the COD, NH4 +–N, TN, and TP effluent of 24 (18–31), 0.4 (0–0.8), 10.6 (8.8–12.9), and 0.31 (0.1–0.5) mg/L under the operational condition of hydraulic retention time (HRT) 7.5 h, recycle ratio 200 %, and dissolved oxygen 3 mg/L. The MBR enhanced NH4 +–N, TN, and TP removal rates of 13, 10, and 18 %, respectively, and the membrane retention reduced TP 0.17 mg/L. The process was able to maintain a stable performance with high-quality effluent. Analysis of the results by fluorescence in situ hybridization showed that the abundance of ammonia-oxidizing bacteria, nitrite-oxidizing bacteria, and phosphorus accumulating organisms as percentages of all bacteria in each compartment was stable. The enriched microorganisms in the system appear to be the main drivers of the process efficient for nutrient removal.  相似文献   

15.
Two sets of lab-scale sequencing batch reactors (SBR), i.e., control SBR and SBR using zeolite as carrier (zeo-SBR), were applied to assess nitrogen removal efficiency. The test results revealed that zeolite powder added in SBR could improve its performance. Due to the combination of zeolite adsorption for NH4 +–N and enhanced simultaneous nitrification and de-nitrification (SND), a higher removal ratio of ammonia nitrogen in wastewater was observed in the test reactor, and the introduction of zeolite powder was helpful to inhabit sludge bulging comparing with the control SBR, in other words, activated sludge immobilized by zeolite powder could remove NH4 +–N, COD, and PO4 significantly in a shorter cycle time. Applied two hydraulic retention times (HRTs) showed that the nitrogen and phosphorus removal could be improved while adapting to load variations.  相似文献   

16.
Performance of moving bed biofilm reactor system for a real hospital wastewater (HW) was experimented, modelled, and optimized using response surface methodology. Prior to conducting laboratory tests, design of the experiments was evaluated to minimize any prediction error. Statistical analyses demonstrated the models’ validity and adequacy for anticipation of the removal of BOD and COD by the process. The models predictions (with desirability of 0.98) were found to be in very good agreement with confirmative experiments results. The results indicated that under convenient operating conditions of the studied variables (packing rate 70%, HRT 24 h, and MLSS 3000 mg/L), the removal efficiencies for BOD and COD were 97.8 and 95.6%, respectively. Moreover, kinetics of the biological process showed that removal of organic matters for the tested wastewater adheres to modified Stover–Kincannon model with a correlation coefficient of 0.998. Ratio of BOD to COD of 0.6 (optimal range for biological treatment normally is >0.5) suggests acceptable efficiency of the reactor for decomposing organic load. A high overall efficiency of the process and fulfilling the related standards make this system an appropriate option for treating HDW.  相似文献   

17.
吗啉废水的生化处理工艺   总被引:2,自引:0,他引:2  
以含有吗啉、甲基吗啉的高浓度有机废水为研究对象,提出了曝气吹脱-吸附-生物处理的联合工艺,并在室内进行了小试实验。结果表明:原废水经过2次曝气吹脱后,ρ(NH3-N)从62 500 mg/L降为431 mg/L,ρ(COD)从50 840 mg/L降为26 051 mg/L。通过吸附实验,ρ(COD)从26 051 mg/L降为2 769 mg/L,ρ(NH3-N)从412 mg/L降为134 mg/L。在生物处理室内小试实验中,采用了活性污泥反应器与曝气生物滤池相结合的处理工艺。在活性污泥反应系统中,当废水pH为7.5、ρ(DO)为4.3 mg/L、水力停留时间为30 h时,COD的去除率最高,可以达到83.1%。在曝气生物滤池中,当ρ(DO)为3.3 mg/L时,COD去除率最高,达到55.8%。在生物处理的最佳参数条件下进行连续监测,当进水ρ(COD)为2 769 mg/L、出水ρ(COD)平均值为387 mg/L时,COD去除率可达到85.9%。吗啉废水经过此联合工艺的处理,ρ(COD)从50 840 mg/L降为387 mg/L。  相似文献   

18.
Pit latrines are the most frequently used sanitation systems in developing countries because of weak infrastructure and poor economic wealth. A modified ventilated improved pit latrine, with a biological filter beneath is proposed to stabilize and to remove the bulk of the nitrogen from the liquid phase. Although the hydraulic loading rate in the proposed biological filter system was calculated to be ca 36 L/m2/d, significantly lower than the rates that are typical applied in standard rate biological filters (in the range of 1000–4000 L/m2/d) used to treat domestic wastewater; the total Kjeldahl nitrogen and chemical oxygen demand concentrations are significantly higher in faecal sludge, namely 3–5 g /L and 20–50 g /L, respectively compared to ca 60 mg/L and 500 mg/L in standard rate biological filters. The biological filter was operated at nitrogen loading rates of 72, 145, 290 and 435 g/m2/d, respectively, until stable state conditions were obtained. The biological filter showed effective nitrogen removal between 72 and 434 g/m2/d and the best total nitrogen removal was obtained at 145 g/m2/d, namely 92 %. These results suggest that it should be possible to remove nitrogen effectively using a biological filter beneath a modified ventilated improved pit latrine.  相似文献   

19.
Over a period of 4 years and 4 months, the geopurification installations at Dehesas de Guadix (Granada, Spain) were monitored to determine the impact on soil and groundwater of the controlled discharge of urban wastewater, and also to identify the best indicators of the entry of the recharged water into the aquifer. The installations are located in an area where the climate is Mediterranean sub-arid, with an average precipitation of less than 287 mm/year, and a rate of evapotranspiration that is almost three times greater. The system was controlled by determining the balance of majority nutrients and boron in the soil and in the groundwater, both at the points affected directly by the wastewater discharge and at others. The quantity of mass discharged was relatively large (COD 14,656 g/m2, NO3 85 g/m2, NO2 4 g/m2, NH4 2,425 g/m2, PO4 1,143 g/m2, K 1,531 g/m2, B 63 g/m2). It was observed that the elimination of nutrients within the soil (COD 97.5%, PO4 94.4%, K 59.17%, N total 18.8%, B 12.69%) was very efficient except for the nitrogen, which nevertheless did not reach the groundwater, as it was eliminated at deep levels of the unsaturated zone. Only 12.69% of the boron was removed, and appreciable, increasing amounts of this element did reach the groundwater. Unexpectedly, none of the majority nutrients behaved as a reliable indicator of the impact on groundwater; despite this, the boron and the bicarbonate did clearly reflect the arrival of the recharged water, and are proposed as the best indicators.  相似文献   

20.
The aim of the study was to investigate the nutrient removal rate of three wastewater protozoan isolates. The study was carried out in a laboratory-scale batch reactor for a period of 120 h. in a four batch study. Aliquot samples were withdrawn from the reactor every 24 h. for the analysis of phosphate, nitrate, nitrite, ammonia, chemical oxygen demand, dissolved oxygen and pH, using standard methods. The results obtained in the different batches among the three isolates showed PO4 2? removal rate ranging from 0.04 to 0.52 mg-PO4 2?/L/h. while NO3 ? nitrate removal rates ranged from 0.08 to 0.16 mg-NO3 ?/L /h. Also NO2- and NH3 rates were observed to range between 0.022 and 0.087 mg-NO2 ?/L /h. 0.05 and 0.16 mg-NH3 ?/L /h, respectively. For the physicochemical parameters, there was no observed COD decrease; rather there was an increase and this was irrespective of isolates and experimental batches. However, dissolved oxygen concentration decreased drastically (below 1 mg/L) at the end of each batch while pH show a decrease after an initial 24 h. period and thereafter increased. This trend was also irrespective of isolates and experimental batches. Overall, the study has been able to show the effect of the test isolates on nutrient removal rates and other physicochemical parameters (COD, DO and pH) in activated sludge mixed liquor.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号