首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Validation of a field filtration technique for characterization of suspended particulate matter from freshwater. Part II. Minor, trace and ultra trace elements
Authors:Fredrik dman  Thomas Ruth  Ilia Rodushkin  Christer Pontr
Institution:aDivision of Applied Geology, Luleå University of Technology, SE-971 87 Luleå, Sweden;bAnalytica AB, Aurorum 10, SE-977 75 Luleå, Sweden;cAnalytica AB, Box 511, SE-183 25 Täby, Sweden
Abstract:A field filtration method for the concentration and separation of suspended particulate matter (SPM) from freshwater systems and the subsequent determination of minor, trace and ultra trace elements (As, Ba, Be, Cd, Co, Cr, Cs, Cu, Ga, Hf, Mo, Nb, Ni, Pb, Rb, Sb, Sc, Sn, Sr, Ta, Th, Tl, U, V, W, Zn and Zr) is validated with respect to detection limits, precision and bias. The validation comprises the whole procedure including filtration, sample digestion and instrumental analysis. The method includes two digestion procedures (microwave acid digestion and alkali fusion) in combination with inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma quadrupole mass spectrometry (ICP-QMS). Total concentrations of these 27 trace and minor elements have been determined in suspended particulate matter (SPM) from lake and river water with low levels of suspended solids (<2 mg L−1 DW), and a wide range of element concentrations. The precision of the method including filtration, digestion and instrumental determination ranges between 8% and 18% RSD for most elements on a dry weight basis. Higher recovery after acid digestion is found for some elements, probably because of volatilization or retention losses in the fusion procedure. Other elements show higher recovery after fusion, which is explained by more efficient decomposition of refractory mineral phases relative to the non-total acid digestion. Non-detectable concentrations of some elements are reported due to small differences between blank filter levels and the amounts of elements present on the filters after sampling. The method limits of detection range between 0.7 ng and 2.65 μg, as estimated from the blank filter samples. These detection limits are 10–550 times higher compared to the corresponding instrumental limits of detection. The accuracy and bias of the overall analytical procedure was assessed from replicate analysis of certified reference materials. A critical evaluation of the instrumental capabilities of the ICP-QMS instrumentation in comparison with a double focusing sector field plasma mass spectrometry technique (ICP-SFMS) is also included. It was found that a modified microwave acid digestion procedure in combination with ICP-SFMS could replace ICP-AES determinations and fusion digestions for most of the investigated elements. Guidelines and limitations for this time- and labour- efficient procedure, offering accurate results for the majority of elements studied are discussed.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号