首页 | 本学科首页   官方微博 | 高级检索  
     检索      


INTERACTION BETWEEN AIRGUNS*
Authors:S VAAGE  B URSIN  K HAUGLAND
Abstract:In the design of linear airgun arrays the interaction between the airguns is usually neglected. We review the different formulae which have been proposed for the minimum separation between airguns at which the interaction is negligible. These formulae can all be approximated by a linear function of a single variable. We have analyzed a large number of measurements in order to establish the amount of interaction between two airguns of various volumes at different pressures and depths. The resulting far-field signature has been measured and compared with the sum of the signatures from the two airguns measured in the same experimental situation. The changes in primary pulse amplitude, bubble period and primary/bubble peak-to-peak amplitude ratio were computed from the measurement data as a function of airgun separation, chamber volume, chamber pressure and airgun depth. The influence of a waveshape kit was investigated, and the effects of interaction and the effects of using a waveshape kit were compared.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏