首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Local measurement for structural health monitoring
Authors:Email author" target="_blank">G?Z?QiEmail author  Guo?Xun  Qi?Xiaozhai  W?Dong  P?Chang
Institution:1. InfraTech, Inc. Silver Spring, Maryland, USA
2. Instutute of Engineering Mechanics, CEA, Harbin, China
3. Risk Management Solution, San Francisco, California, USA
4. Department of Civil Engineering, University of Maryland/College Park, USA
Abstract:Localized nature of damage in structures requires local measurements for structural health monitoring. The local measurement means to measure the local, usually higher modes of the vibration in a structure. Three fundamental issues about the local measurement for structural health monitoring including (1) the necessity of making local measurement, (2) the difficulty of making local measurement and (3) how to make local measurement are addressed in this paper. The results from both the analysis and the tests show that the local measurement can successfully monitor the structural health status as long as the local modes are excited. Unfortunately, the results also illustrate that it is difficult to excite local modes in a structure. Therefore, in order to carry structural health monitoring into effect, we must (1) ensure that the local modes are excited, and (2) deploy enough sensors in a structure so that the local modes can be monitored.
Keywords:structure health monitoring  local measurement  local modes  higher modes  local modes  excitation  sensors  structural vibration
本文献已被 CNKI 维普 万方数据 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏