首页 | 本学科首页   官方微博 | 高级检索  
     

浅谈钻孔抽水试验的设计与实施
引用本文:罗岚. 浅谈钻孔抽水试验的设计与实施[J]. 安徽地质, 2012, 0(3): 217-219
作者姓名:罗岚
作者单位:安徽省地质矿产勘查局327地质队,安徽 合肥 230011
摘    要:钻孔抽水试验时,试抽出的钻孔涌水量远远超出预测且降深也无法满足规程要求时,只有根据试抽水的结果,重新设计抽水试验方案,重新选择井管的内径、抽水设备以及参数,风、测管的口径和下入深度等.本文通过一个钻孔抽水试验的经过,说明按规程选择以上各参数的方法及意义.

关 键 词:抽水试验  设计  大流量  实施

On design and implementation of borehole pumping test
LUO Lan. On design and implementation of borehole pumping test[J]. Geology of Anhui, 2012, 0(3): 217-219
Authors:LUO Lan
Affiliation:LUO Lan(No.327 Geological Party of Bureau of Geology and Mineral Exploration of Anhui Province,Hefei,Anhui 230011,China)
Abstract:During borehole pumping test,if the pumped-out water yield is far more than the expected and the dropdown cannot meet the requirement,the only way is to redesign pumping test scheme according to trial pumping result,including re-choosing inner diameter of well pipe,pumping equipment and parameters,wind pipe and gauging pipe size and landing depth.This paper,based on a borehole pumping test process,told the method of choosing abovementioned each parameter according to standards and the implications.
Keywords:pumping test  design  high flow  implementation
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号