Comparison of flux measurements with open- and closed-path gas analyzers above an agricultural field and a forest floor
Authors:Xuhui Lee  T Andrew Black  Michael D Novak
Institution:(1) Department of Soil Science, University of British Colombia, V 6T 1Z4 Vancouver, B.C., Canada
Abstract:Comparison was made of the flux measurements of a closed-path CO2/H2O analyzer and an open-path H2O analyzer above a clover field and the forest floor of a Douglas-fir stand. The attenuation of the gas concentration fluctuations caused by the sampling tube of the closed-path analyzer resulted in underestimation of the H20 flux above both surfaces. The degree of underestimation above the clover field depended on wind speed, but was smaller than that calculated from the transfer function for laminar flow in a circular tube and the scalar cospectrum in the neutral and unstable surface layer. Above the forest floor CO2 fluctuations led those of H2O by sim0.7s. The implications of this are discussed regarding the determination of the time delay caused by the sampling tube of the closedpath analyzer. The day-time CO2 efflux from the forest floor, averaged over three days, was 0.043 mg/(m2s).