首页 | 本学科首页   官方微博 | 高级检索  
     

Qualification Test for the Reliability of Diver Gas Recovery System
作者单位:Mao Fangguan,Lu Shunchang and Luo Ruiren Senior Engineer,The Naval Medical Research Institute,Shanghai 200433. Senior Engineer,The Navigation Guarantee Department of the Chinese Navy Headquarters,Tianjin 300042
摘    要:A qualification test for the reliability of a newly-developed Diver Gas Recovery System(DGRS)was carried out in the Naval Medical Research Institute of the People's Liberation Army,Chinafrom March 29 to April 2,1995.A sequential test plan of high discrimination ratio for the mean time be-tween failures(MTBF)was adopted.The test procedures simulated those of a 300 msw dive.A hyperbaricbreathing machine was used for the simulation of diver's respiratory functions.Parameters,such as divingdepth,respiratory minute volume(RMV),CO_2 production,gas flow rate,partial pressure of carbondioxide,and ambient temperature and himidity were all displayed and recorded with a microcomputer sys-tem.The results indicated that no failure occurred during the 91.5 h operation.According to the accept-ance and rejection criteria specified in the statistical test plan,a no-failure score in the 88 h operation is ac-ceptable.Therefore,the DGRS has been demonstrated to meet the requirements of MTBF specified in thecontract.


Qualification Test for the Reliability of Diver Gas Recovery System
Mao Fangguan,Lu Shunchang and Luo Ruiren Senior Engineer,The Naval Medical Research Institute,Shanghai . Senior Engineer,The Navigation Guarantee. Qualification Test for the Reliability of Diver Gas Recovery System[J]. China Ocean Engineering, 1997, 0(3)
Authors:Mao Fangguan  Lu Shunchang  Luo Ruiren Senior Engineer  The Naval Medical Research Institute  Shanghai . Senior Engineer  The Navigation Guarantee
Affiliation:Mao Fangguan,Lu Shunchang and Luo Ruiren Senior Engineer,The Naval Medical Research Institute,Shanghai 200433. Senior Engineer,The Navigation Guarantee Department of the Chinese Navy Headquarters,Tianjin 300042
Abstract:A qualification test for the reliability of a newly- developed Diver Gas Recovery System (DGRS) was carried out in the Naval Medical Research Institute of the People's Liberation Army, China from March 29 to April 2, 1995. A sequential test plan of high discrimination ratio for the mean time between failures (MTBF) was adopted. The test procedures simulated those of a 300 msw dive. A hyperbaric breathing machine was used for the simulation of diver's respiratory functions. Parameters, such as diving depth, respiratory minute volume (RMV), CO2 production, gas flow rate, partial pressure of carbon dioxide, and ambient temperature and himidity were all displayed and recorded with a microcomputer system. The results indicated that no failure occurred during the 91.5 h operation. According to the acceptance and rejection criteria specified in the statistical test plan, a no-failure score in the 88 h operation is acceptable. Therefore, the DGRS has been demonstrated to meet the requirements of MTBF specified in the contract.
Keywords:diver gas recovery system  reliability  qualification test