摘    要:铀、钍在地壳中的含量平均约3ppm至8ppm。地球化学探矿样品一般要求测定低于地壳平均值的含量,如1—2ppm的铀或钍。在一次分离的溶液中测定两个痕量元素是最可取的。Pollock在抗坏血酸存在下以硼酸掩蔽氟,用TOPO(三辛基氧膦)的环己烷溶液一次萃取铀


TOPO Extraction-Photometric Method for Simultaneous Determination of Uranium and Thorium in Geochemical Samples
Abstract:The sample solution in 2 N nitric acid tnediurn was extracted with trioctyl- phosphine oxide (TOPO) in cyclo,hexane solution in the present of ascobic acid, boric acid and aluminium salts, and backextracting with 2 N-HN03 contain ing 0.8% NH4F solution. Uranium was determined in TOPO layer with 5-Br- PADa1P, and thorium was determined in aqueous solution with arsenazo III.Its C. V. for sample containing 1.3ppm U and 1.6ppm Th were 9·0% and 3 .6% respectively (n=8).