首页 | 本学科首页   官方微博 | 高级检索  
     

泰安地震台GM-4仪观测中台阶干扰分析
引用本文:刘敏,陈传华,张素琴. 泰安地震台GM-4仪观测中台阶干扰分析[J]. 地震地磁观测与研究, 2012, 33(2): 74-79
作者姓名:刘敏  陈传华  张素琴
作者单位:1. 中国济南250014 山东省地震局;中国北京100871 北京大学地球与空间科学学院
2. 中国泰安271000 泰安基准地震台
3. 中国北京100081 中国地震局地球物理研究所
基金项目:中国地震局三结合项目,*
摘    要:自2008年12月以来,泰安地震台的地磁观测数据在Z分量一直存在一种出现时间和持续时间长度均不规则的小幅度台阶干扰.分析此种干扰的特点,在泰安地震台的相对记录室、绝对观测室和山洞等不同场地进行实地对比观测试验,确定干扰仅出现在相对记录室,应属于供电干扰.通过排查分析,最终确定照明电路是导致该干扰的原因.

关 键 词:地磁观测干扰  Z分量  台阶干扰  照明电路

Reason for the steps in the GM-4 fluxgate magnetometer observation at Taian Seismic Station
Liu Min , Chen Chuanhua , Zhang Suqin. Reason for the steps in the GM-4 fluxgate magnetometer observation at Taian Seismic Station[J]. Seismological and Geomagnetic Observation and Research, 2012, 33(2): 74-79
Authors:Liu Min    Chen Chuanhua    Zhang Suqin
Affiliation:1) Earthquake Administration of Shandong Province, Jinan 25001, China 2) School of Earth and Space Sciences ,Peking University, Beijing 100871, China3) Taian Standard Seismic Station, Shandong Province 271000, China 4) Institute of Geophysics, China Earthquake Administration, Beijing 100081, China
Abstract:There has been disturbances of small steps in the vertical component (Z component) of the geomagnetic observation at Taian Observatory since December 2008 with no repetition in the occurring time and the lasting period. Based on the review of the characteristics of the disturbances, we carried out comparison observation with another instrument of different type in addition to the running GM-4 magnetometer. The comparison results showed that this kind of disturbances appeared only in the variometer room. After estimating each part of the electronic circuitry, the illuminating circuitry was cut off and the steps never showed up later. Something in the illuminating circuitry seemed to be the reason for the steps in the magnetic observation.
Keywords:disturbances in geomagnetic observation   Z component   steps   illuminating circtfitry
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号