某水电站坝前堆积体稳定性的三维数值模拟分析
引用本文:朱继良,黄润秋.某水电站坝前堆积体稳定性的三维数值模拟分析[J].岩土力学,2005,26(8):1318-1322.
作者姓名:朱继良  黄润秋
作者单位:成都理工大学,地质灾害防治与地质环境保护国家专业实验室,成都,610059
摘    要:某水电站坝前堆积体边坡的稳定性关系到该大坝的建设与运营。野外工作发现,它是深切冲沟型崩塌式堆积体,由下伏基岩和松散的堆积物组成。在1360~1450m高程之间堆积体有一个较为明显的收口转向特征,这有利于增加其稳定性。在野外工作的基础上,采用目前较为通用的两种三维有限元软件(3D-Sigma和3D-Flac)对其稳定性进行数值模拟研究。结果表明:(1)堆积体的应力场主要表现为以自重应力场为主,其应力分布主要受岩性控制;(2)堆积体的潜在滑动面为堆积体与其下伏基岩接触部位的一定范围内;(3)堆积体的位移表现为向坡外(临空面方向)滑移,且中前缘的位移量相对较大;(4)堆积体前缘的收口效应改善了其应力状态,增加了稳定性;(5)堆积体的整体稳定性较好,在1472~1610m高程之间的堆积体有可能发生局部的中浅层破坏。

关 键 词:水电站  堆积体  三维数值模拟  稳定性
文章编号:1000-7598-(2005)08-1318-05
收稿时间:2004-07-05
修稿时间:2004年7月5日

Study on stability of talus slope in front of a dam in a huge hydroelectric station by using 3D numerical simulation
ZHU Ji-liang,HUANG Run-qiu.Study on stability of talus slope in front of a dam in a huge hydroelectric station by using 3D numerical simulation[J].Rock and Soil Mechanics,2005,26(8):1318-1322.
Authors:ZHU Ji-liang  HUANG Run-qiu
Institution:National Laboratory of Geo-hazards Prevention and Geo-environment Protection , Chengdu University of Technology, Chengdu 610059, China
Abstract:The stability of the talus slope is important to its construction and operation. We draw a conclusion on site that it is a incised gully collapsing talus slope that are consisted of bedrock and unconsolidated deposit. There are evidence close up and turn around between the elevations of 1 360-1 450 m, the elevations of elevation which are contributed to its stability. The data that by using 3D numerical simulation (3D-Sigma and 3D-Flac) show that ⑴Stress field of the talus slope is main weight field, its stresses distributes is mainly controlled by lithology; ⑵ Latent sliding surface is the interface of talus and the bedrock and above it in some height. ⑶ The displacement is toward to limit surface; and the displacement of the middle-front part of the talus slope is large; ⑷ The front zone’s close up improves stress state and raises the stability of talus slope; ⑸ It is wholly stable, but it maybe occurs middle-superficial layer failure between the elevations of 1 472-1 610 m .
Keywords:hydroelectric station  talus slope  3D numerical simulation  stability