首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Seismic reliability analysis of urban water distribution network
Authors:Jie Li  Shulin Wei  Wei Liu
Institution:1. Building Engineering Department, Tongji University, Shanghai 200092, China; State Key Laboratory for Disaster Reduction in Civil Engineering, Shanghai 200092, China
2. China Construcion (Shenzhen) Design International, Shanghai 200233, China
3. Building Engineering Department, Tongji University, Shanghai 200092, China
Abstract:An approach to analyze the seismic reliability of water distribution networks by combining a hydraulic analysis with a first-order reliability method (FORM), is proposed in this paper. The hydraulic analysis method for normal conditions is modified to accommodate the special conditions necessary to perform a seismic hydraulic analysis. In order to calculate the leakage area and leaking flow of the pipelines in the hydraulic analysis method, a new leakage model established from the seismic response analysis of buried pipelines is presented. To validate the proposed approach, a network with 17 nodes and 24 pipelines is investigated in detail. The approach is also applied to an actual project consisting of 463 nodes and 767 pipelines. The results show that the proposed approach achieves satisfactory results in analyzing the seismic reliability of large-scale water distribution networks.
Keywords:water distribution network  leakage model  hydraulic analysis  FORM  seismic capacity reliability
本文献已被 CNKI 维普 万方数据 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏