Effects of Column Diameter on Setting Behavior of Dredged Slurry in Sedimentation Experiments |
| |
Authors: | Yu-Feng Gao Yuan Zhou Da-yong Li |
| |
Affiliation: | 1. Geotechnical Research Institute, Hohai University, Nanjing, P. R. China;2. College of Civil Engineering and Architecture, Shandong University of Science and Technology, Qingdao, P. R. China |
| |
Abstract: | This article investigates the influence of dimensions of a settling column on the settling mode and the settling rate. End conditions of the settling stage in the hindered settling were also analyzed. It was found that the settling mode in a column with a smaller diameter tends to be consolidation settling. The effect of a settling column wall decreases with increasing column diameter, and it can be ignored provided the column diameter is larger than 14.5 centimeters. For the difference in initial water content, the settling behavior of the slurry develops a different sensitivity to the diameter effect. The influence of column diameter reduces as the initial water content of the slurry becomes higher. It is suggested that the internal diameter of the column used in a sedimentation experiment should be 14.5 centimeters. |
| |
Keywords: | dredged slurry equilibrium water content internal diameter of column sedimentation settling mode settling rate |
|
|