ANALYSIS AND IMPROVEMENT OF THE PRIMARY FIELD WAVEFORM OF THE GROUND TEM METHOD* |
| |
Authors: | BIN QIAN |
| |
Abstract: | Many ground TEM systems use an on-off type of primary field waveform and measure the secondary field only in the transmitter off-time, so as to realize the pure secondary field measurement. The width of the trailing edge of the primary pulses and the duration of the transmitter on-time form a time-constant (Tc) window. Most effective excitation is achieved if the target conductor has a Tc falling into this window. To be able to measure in the transmitter on-time, two primary field waveforms are proposed. The first is a series of unipolar pulses with identical steep ramps at both leading and trailing edges. Measurements made in the on-time after the leading edges simply reduce the stacking time needed and power consumption by half. Also, long- Tc conductors are better excited. The second is a series of bipolar pulses with long ramps as the leading edges and short ramps as the trailing edges. This waveform presents two different Tc-windows at the same time and helps to improve the detection of long-Tc conductors in the presence of short- Tc ones. |
| |