Filtrate Quality from Different Filter Operations
Authors:Robert I Mackie  Micha&#x; Zielina  Wojciech Dabrowski
Institution:Robert I. Mackie,Micha? Zielina,Wojciech Dabrowski
Abstract:A brief review of the literature on filtrate quality obtained in constant and variable declining rate operation systems is presented, with the general conclusion that both systems usually produce filtrate of similar quality, assuming the flow‐rate controllers in the constant flow rate system operate properly. A mathematical model of CR (constant rate) filters and VDR (variable declining rate) filters based on the model by Mackie and Zhao (1999) has been described and used to investigate filtrate quality under different operating conditions. A similar quality of filtrate was achieved in computations carried out for both modes of operation, while the total head loss was much lower in the VDR mode. For the same time of filter runs slightly better filtration quality resulted from CR operation, but for different filter runs resulting from the same head loss of flow just before a backwash, the VDR control system produced lower turbidity filtrate.
Keywords:Water Treatment  Variable Declining Rate Filter  Deep Bed Filtration  Unit Bed Element Model  Non‐homogeneous Suspension Solids  Wasseraufbereitung  Abnehmende Filtergeschwindigkeit  Tiefenfiltration  Strö  mungsmodell der elementaren Filterschicht  Polydisperse Suspension