Bearing Capacity of a Model Scale Footing on Crude Oil-Contaminated Sand
Authors:EC Shin  JB Lee  BM Das
Institution:(1) Department of Civil Engineering, University of Gaziantep, 27310 Gaziantep, Turkey
Abstract:Onshore and offshore oil spills contaminate soil. In addition to environmental concerns for ground water pollution and other possible effects, the geotechnical properties of the contaminated soil such as the shear strength and the hydraulic conductivity are also altered. This note is a report of research in progress to evaluate the variation of the shear strength of a sand contaminated by a crude oil and thus the ultimate bearing capacity of shallow foundations. The limited results of the tests reported here relate to only one type of sand and one crude oil. The oil content was varied from zero to 4.2%. Results of direct shear tests for determining the soil friction angle are given. Along with these, laboratory model test results for the ultimate bearing capacity of a surface strip foundation supported by crude oil-contaminated sand are also presented. Based on these test results, the effect of oil contamination in drastically reducing the bearing capacity is discussed.
Keywords:
本文献已被 SpringerLink 等数据库收录!