首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Identifying groundwater pumping source information using simulated annealing
Authors:Yu‐Chung Lin  Hund‐Der Yeh
Institution:Institute of Environmental Engineering, National Chiao Tung University, No.75, Po‐Ai Street, Hsinchu City 300, Taiwan
Abstract:This study develops an approach referred to as SA‐MF using simulated annealing (SA) and a three‐dimensional groundwater flow model (MODFLOW‐2000) to determine the pumping source information, namely the pumping source location, the pumping rate and the pumping period. Eight scenarios, each with various cases for aquifers with homogeneous or heterogeneous conductivities, are used to test the applicability and accuracy of SA‐MF in determining the pumping source information. The results show that at least five measured heads should be used to analyse the pumping source identification problem and at least three observation wells are required to effectively determine the pumping source information. The SA‐MF gives good estimated results in both synthetic and real problems even if the measured heads contain measurement errors. Copyright © 2008 John Wiley & Sons, Ltd.
Keywords:groundwater  inverse problem  heuristic approach  pumping source identification  simulated annealing