首页 | 本学科首页   官方微博 | 高级检索  
     

Revision of seismic design codes corresponding to building damagesin the “5.12” Wenchuan earthquake
作者单位:Institute of Earthquake Engineering,China Academy of Building Research,Beijing 100013,China 
基金项目:National Natural Science Foundation of China Under Grant No.50439010; NSFC and Korea Science and Engineering Foundation Under Grant No.50811140341
摘    要:A large number of buildings were seriously damaged or collapsed in the 5.12 Wenchuan earthquake. Based on field surveys and studies of damage to different types of buildings, seismic design codes have been updated. This paper briefly summarizes some of the major revisions that have been incorporated into the Standard for classification of seismic protection of building constructions GB50223-2008 and Code for Seismic Design of Buildings GB50011-2001. The definition of seismic fortification class for buildings has been revisited, and as a result, the seismic classifications for schools, hospitals and other buildings that hold large populations such as evacuation shelters and information centers have been upgraded in the GB50223-2008 Code. The main aspects of the revised GB50011-2001 code include: (a) modification of the seismic intensity specified for the Provinces of Sichuan, Shanxi and Gansu; (b) basic conceptual design for retaining walls and building foundations in mountainous areas; (c) regularity of building configuration; (d) integration of masonry structures and precast RC floors; (e) requirements for calculating and detailing stair shafts; and (f) limiting the use of single-bay RC frame structures. Some significant examples of damage in the epicenter areas are provided as a reference in the discussion on the consequences of collapse, the importance of duplicate structural systems, and the integration of RC and masonry structures.

关 键 词:Wenchuan  earthquake  earthquake  damage  to  buildings  revision  of  seismic  design  codes
收稿时间:2009-10-12

Revision of seismic design codes corresponding to building damages in the 5.12 Wenchuan earthquake
Yayong Wang. Revision of seismic design codes corresponding to building damages in the 5.12 Wenchuan earthquake[J]. Earthquake Engineering and Engineering Vibration, 2010, 9(2): 147-155. DOI: 10.1007/s11803-010-0001-9
Authors:Yayong Wang
Affiliation:Institute of Earthquake Engineering,China Academy of Building Research,Beijing 100013,China
Abstract:A large number of buildings were seriously damaged or collapsed in the “5.12” Wenchuan earthquake. Based on field surveys and studies of damage to different types of buildings, seismic design codes have been updated. This paper briefly summarizes some of the major revisions that have been incorporated into the “Standard for classification of seismic protection of building constructions GB50223-2008” and “Code for Seismic Design of Buildings GB50011-2001.” The definition of seismic fortification class for buildings has been revisited, and as a result, the seismic classifications for schools, hospitals and other buildings that hold large populations such as evacuation shelters and information centers have been upgraded in the GB50223-2008 Code. The main aspects of the revised GB50011-2001 code include: (a) modification of the seismic intensity specified for the Provinces of Sichuan, Shanxi and Gansu; (b) basic conceptual design for retaining walls and building foundations in mountainous areas; (c) regularity of building configuration; (d) integration of masonry structures and pre-cast RC floors; (e) requirements for calculating and detailing stair shafts; and (f) limiting the use of single-bay RC frame structures. Some significant examples of damage in the epicenter areas are provided as a reference in the discussion on the consequences of collapse, the importance of duplicate structural systems, and the integration of RC and masonry structures.
Keywords:Wenchuan earthquake  earthquake damage to buildings  revision of seismic design codes
本文献已被 CNKI 维普 万方数据 SpringerLink 等数据库收录!