高灵敏度电子地震预警器故障检测方法研究
引用本文:温宏愿.高灵敏度电子地震预警器故障检测方法研究[J].西北地震学报,2018,40(6):1389-1395.
作者姓名:温宏愿
作者单位:南京理工大学泰州科技学院, 江苏 泰州 225300;香港大学, 香港 999077
基金项目:江苏省"333工程"科研资助项目(BRA2016177);江苏高校境外研修计划资助(苏教办师[2018]3号);江苏省高校"青蓝工程"人才项目资助(苏教办师[2016]1号);泰州市科技支撑计划(社会发展)项目(TS201819)
摘    要:传统基于时间序列数据挖掘的故障检测方法,缺少高灵敏度电子地震预警器灵敏度分析,故障检测率低。提出新的高灵敏度电子地震预警器故障检测方法,根据高灵敏度电子地震预警器的结构,采用质量块、铰链和延长梁构建其力学模型,得到电子预警器的灵敏度表达式,根据该表达式建立多信号模型相关矩阵,得到故障优先概率的故障源耗费,采用基于故障模式故障概率的改进多信号模型检测方法(包括故障模式概率均分法和故障模式概率优先法),计算得到电子地震预警器故障概率表达式,实现电子地震预警器故障检测。实验结果表明,所提方法对电子地震预警器TE过程中G和I两个指标的故障检测率分别为0.989、0.905,对PL过程的故障检测时刻为180 s、故障检测率为0.412 8,都高于传统基于时间序列数据挖掘的故障检测方法,说明所提方法具有较高的故障检测性能。

关 键 词:高灵敏度  电子地震预警器  故障检测  多信号模型  概率均分法  概率优先法
收稿时间:2018/8/20 0:00:00

A NewFault Detection Method for High-sensitivity Electronic Early-warning Device
WEN Hongyuan.A NewFault Detection Method for High-sensitivity Electronic Early-warning Device[J].Northwestern Seismological Journal,2018,40(6):1389-1395.
Authors:WEN Hongyuan
Institution:Taizhou Institute of Sci. & Tech., NJUST, Taizhou 225300, Jiangsu, China;The University of Hong Kong, Hong Kong 999077, China
Abstract:The traditional fault detection method based on time-series data mining cannot perform sensitivity analyses of the high-sensitivity electronic earthquake early-warning device, and its fault detection rate is low. In this paper, we propose a new fault detection method for the high-sensitivity electronic earthquake warning device. Based on the device structure, we constructed a mechanical model using a mass block, hinge, and extended beam to obtain the sensitivity expression of the device. According to this expression, we established a multi-signal model correlation matrix, and obtained the fault source cost of the fault preemption probability. We adopted an improved multi-signal model detection method based on the fault probability of the fault mode in detecting faults of the electronic earthquake warning device. The experimental results show that the fault detection rates of the two indicators G and I in the TE process of the electronic earthquake warning device are 0.989 and 0.905, respectively, the fault detection time of the PL process is 180 s, and the fault detection rate is 0.412 8. These values are all higher than those obtained by the traditional fault detection method based on time-series data mining, which shows that the proposed method has higher fault detection performance.
Keywords:high sensitivity  electronic earthquake early-warning device  fault detection  multi-signal model  probability sharing method  probability priority method