首页 | 本学科首页   官方微博 | 高级检索  
     


An international turbulence comparison experiment (ITCE 1976)
Authors:A. J. Dyer  J. R. Garratt  R. J. Francey  I. C. McIlroy  N. E. Bacon  P. Hyson  E. F. Bradley  O. T. Denmead  L. R. Tsvang  Y. A. Volkov  B. M. Koprov  L. G. Elagina  K. Sahashi  N. Monji  T. Hanafusa  O. Tsukamoto  P. Frenzen  B. B. Hicks  M. Wesely  M. Miyake  W. Shaw
Affiliation:1. CSIRO Division of Atmospheric Physics, Aspendale, Victoria, Australia
2. CSIRO Division of Environmental Mechanics, Canberra, Australia
3. Institute of Atmospheric Physics, U.S.S.R. Academy of Science, U.S.S.R.
4. Okayama Univ., Univ. of Osaka, Met. Research Institute, Univ. of Kyoto, Japan
5. Argonne National Laboratory, Argonne, Illinois, USA
7. Univ. of British Columbia, Vancouver, Canada
8. Univ. of Washington, Seattle, USA
Abstract:Turbulence data for the International Turbulence Comparison Experiment (ITCE) held at Conargo, N.S.W. (35° 18′ S., 145° 10′ E.) during October, 1976 are analysed. The standard deviation % MathType!MTEF!2!1!+-% feaafeart1ev1aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn% hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr% 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq-Jc9% vqaqpepm0xbba9pwe9Q8fs0-yqaqpepae9pg0FirpepeKkFr0xfr-x% fr-xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaGaaiikaiqado% hagaqbamaaCaaaleqabaGaaGOmaaaakiaacMcadaahaaWcbeqaaiaa% igdacaGGVaGaaGOmaaaaaaa!3B93![(s'^2 )^{1/2} ] and covariance % MathType!MTEF!2!1!+-% feaafeart1ev1aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn% hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr% 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq-Jc9% vqaqpepm0xbba9pwe9Q8fs0-yqaqpepae9pg0FirpepeKkFr0xfr-x% fr-xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaWaa0aaaeaace% WG3bGbauaaceWGZbGbauaaaaaaaa!3809![overline {w's'} ] measured by a number of instruments and instrument arrays have been compared to assess their field performance and calibration accuracy. Satisfactory agreement, i.e. typically 5% for % MathType!MTEF!2!1!+-% feaafeart1ev1aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn% hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr% 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq-Jc9% vqaqpepm0xbba9pwe9Q8fs0-yqaqpepae9pg0FirpepeKkFr0xfr-x% fr-xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaGaaiikamaana% aabaGabm4CayaafaWaaWbaaSqabeaacaaIYaaaaaaakiaacMcadaah% aaWcbeqaaiaaigdacaGGVaGaaGOmaaaaaaa!3BA4![(overline {s'^2 } )^{1/2} ] (except in humidity) and of the order of 20% for % MathType!MTEF!2!1!+-% feaafeart1ev1aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn% hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr% 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq-Jc9% vqaqpepm0xbba9pwe9Q8fs0-yqaqpepae9pg0FirpepeKkFr0xfr-x% fr-xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaGaaiikaiqado% hagaqbamaaCaaaleqabaGaaGOmaaaakiaacMcadaahaaWcbeqaaiaa% igdacaGGVaGaaGOmaaaaaaa!3B93![(s'^2 )^{1/2} ], was achieved, but only after consideration of:
  1. Instrumental response at high frequencies.
  2. Flow distortion induced by instruments and supporting structures.
  3. Spatial separation of instruments used for covariance measurements.
  4. Statistical errors associated with single point measurements over a finite averaging time, and with lateral separation of two sensor arrays being compared.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号