Full-scale dynamic testing of response-controlled buildings and their components:concepts,methods,and findings
Authors:Kazuhiko Kasai  Kazuhiro Matsuda
Abstract:A series of shake-table tests was conducted by inserting and replacing 4 different types of dampers,or by removing them in a full-scale 5-story steel frame building. The objective is to validate response-control technologies that are increasingly adopted for major Japanese buildings without being attested to-date by a major earthquake. Test results are briefly described,and good performance of the dampers and frame demonstrated. The concepts of the full-scale building tests and various contributions are discussed. The difficulty associated with full-scale dynamic testing is explained.
Keywords:response-controlled building  steel frame  steel damper  viscous damper  oil damper  viscoelastic damper