首页 | 本学科首页   官方微博 | 高级检索  
     


Determination of the REE in Geological Reference Materials DTS-1 (Dunite) and PCC-1 (Peridotite) by Ultrasonic and Microconcentric Desolvating Nebulisation ICP-MS
Authors:Jinesh C. Jain  M. Paul Field  Clive R. Neal  James C. Ely  Robert M. Sherrell
Affiliation:Department of Civil Engineering and Geological Sciences, University of Notre Dame, Notre Dame, IN 46556 USA. e-mail:;Institute of Marine and Coastal Sciences, Rutgers University, New Brunswick, NJ 08901 USA
Abstract:Inductively coupled plasma-mass spectrometry is well suited for the precise, accurate and rapid determination of rare earth elements in most geological samples. However, determination of rare earth elements in certain mantle-derived materials, without applying preconcentration techniques, remains problematical due to low natural concentrations (generally < 1 ng g−1). Consequently, USGS reference materials DTS-1 (a dunite) and PCC-1 (a partially serpentinized harzburgite) have only suggested rather than recommended values for the rare earth elements in reference material compilations. We compared results obtained using two ICP-MS instruments: a U-5000AT ultrasonic nebuliser coupled to a PQ2+ quadrupole ICP-MS and an ELEMENT sector field ICP-MS equipped with a MCN-6000 microconcentric desolvating nebuliser, with the suggested literature values for these two reference materials. Precision and accuracy of analytical methods employed by both instruments were demonstrated by excellent relative standard deviations (< 2%) and inter-laboratory agreement (< 5%) for numerous analyses of BHVO-1 and BIR-1, which are well established with rare earth elements contents at the μg g−1 level. Repeat analyses of DTS-1 and PCC-1 at each laboratory indicate that each method is generally precise to better than 5% at sub-g g−1 levels. Furthermore, values from both instruments generally agree to within 10%. Our DTS-1 and PCC-1 values agree reasonably well with selected data reported in the literature (except for Ce and Sm in DTS-1) but exhibit poorer agreement with reported compilation values. With the demonstrated level of precision and accuracy, we contend that these new values for DTS-1 and PCC-1, generated by two different instruments, are the best estimates of the true whole-rock composition of these samples reported to date.
Keywords:rare earth elements    inductively coupled plasma-mass spectrometry    reference materials    DTS-1    PCC-1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号