作者单位:中国地震局地震研究所,武汉,430071
摘    要:TCM-3型测温仪采用Pt100铂电阻作为温度传感元件,结合铂电阻稳定性和重复性好、线性度高的特点及实际应用环境的限制,通过后续电路的设计使TCM-3型测温仪达到了要求的测量精度,并从理论上进行误差分析,检验了其测量精度的可靠性.

关 键 词:TCM-3型硐体测温仪  Pt100铂电阻  温度传感器  后续电路  误差分析
文章编号:1671-5942(2007)Spec.-0111-05
修稿时间:2006年12月10

DESIGN OF TCM-3 THERMOMETER AND ERROR ANALYSIS
Yang Jiang,Lu Chongwu.DESIGN OF TCM-3 THERMOMETER AND ERROR ANALYSIS[J].Journal of Geodesy and Geodynamics,2007,27(Z1):111-115.
Authors:Yang Jiang  Lu Chongwu
Abstract:Combining the characteristics of stability and duplication of Pt100 platinic resistance,limited by the application enviroument,the TCM-3 thermometer uses the Pt100 platinic resistance as the sensor.Through the design of the following electric circuit,the TCM-3 thermometer has achieved the measuring accuracy request,and the theoretic analysis on error examines the reliability of the measuring accuracy.
Keywords:TCM-3 cave thermometer  Pt100 platinic resistance  temperature sensor  following circuit  error analysis