首页 | 本学科首页   官方微博 | 高级检索  
     


Intercomparison of NO_x, SO_2, O_3, and Aromatic Hydrocarbons Measured by a Commercial DOAS System and Traditional Point Monitoring Techniques
Authors:XIE Pinhua  LIU Wenqing  FU Qiang  WANG RuibinLIU Jianguo  WEI QingnongAnhui Institute  of Optics  Fine Mechanics  Chinese Academy of Sciences  Hefei China National Environmental Monitoring Center  Beijing
Affiliation:Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031;China National Environmental Monitoring Center,Beijing,100029
Abstract:A field-based Intercomparison study of a commercial Differential Optical Absorption Spectroscopy (DOAS) instrument (OPSIS AB, Sweden) and different point-sample monitoring techniques (PM, based on an air monitoring station, an air monitoring vehicle, and various chemical methods) was conducted in Beijing from October 1999 to January 2000. The mixing ratios of six trace gases including NO, NO2, SO2, O3, benzene, and toluene were monitored continuously during the four months. A good agreement between the DOAS and PM data was found for NO2 and SO2. However, the concentrations of benzene, toluene, and NO obtained by DOAS were significantly lower than those measured by the point monitors. The ozone levels monitored by the DOAS were generally higher than those measured by point monitors. These results may be attributed to a strong vertical gradient of the NO-O3-NO2 system and of the aromatics at the measurement site. Since the exact data evaluation algorithm is not revealed by the manufacturer of the DOAS system, the error in the DOAS analysis can also not be excluded.
Keywords:Differential optical absorption spectroscopy   urban air pollution   intercomparison   remote-sensing technique
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号