An Extra Large Aperture Scintillometer For Long Range Applications
Authors:W Kohsiek  W M L Meijninger  A F Moene  B G Heusinkveld  O K Hartogensis  W C A M Hillen  H A R De Bruin
Institution:(1) Royal Netherlands Meteorological Institute (KNMI), P.O. Box 201, 3730 AE De Bilt, The Netherlands;(2) Meteorology and Air Quality Group, Wageningen University, Duivendaal 2, 6701 AP Wageningen, The Netherlands
Abstract:An incoherent scintillometer with 0.31-m aperture was testedalong a 9.8-km path over grassland. Scintillometer derived heat fluxes were comparedwith in situ eddy covariance measurements. Albeit with considerable scatter, the fluxescompared well during daytime. During nighttime credible fluxes are also obtained. The scintillometerfunctioned satisfactory for 96% of the 7-week period.
Keywords:Heat flux  Long path length  Scintillometer
本文献已被 SpringerLink 等数据库收录!