首页 | 本学科首页   官方微博 | 高级检索  
     


Empirical Assessment of Ground Water–to-Indoor Air Attenuation Factors for the CDOT-MTL Denver Site
Authors:P.C. Johnson  R.A. Ettinger  J.P. Kurtz  R. Bryan  J.E. Kester
Abstract:The area surrounding the Colorado Department of Transportation Materials Testing Laboratory in Denver was the subject of intense investigation, involving the collection of thousands of ground water, soil-gas, and indoor air samples in order to investigate indoor air impacts associated with a subsurface release of chlorinated solvents. The preremediation portion of that data set is analyzed and reduced in this work to ground water–to-indoor air attenuation factors (αgw= the ratio of the measured indoor air concentration to the soil-gas concentration predicted to be in equilibrium with the local ground water concentration). The empirical αgw values for this site range from about 10−6 to 10−4 with an overall average of 3 × 10−5 (μg/L indoor air)/(μg/L soil gas). The analysis of this data set highlights the need for a thorough data review and data screening when using large data sets to derive empirical relationships between subsurface concentrations and indoor air. More specifically, it is necessary to identify those parts of the data that contain a strong vapor intrusion pathway signal, which generally will require concentrations well above reported detection levels combined with spatial or temporal correlation of subsurface and indoor concentrations.