首页 | 本学科首页   官方微博 | 高级检索  
     


The use of GPR and VES in delineating a contamination plume in a landfill site: a case study in SE Brazil
Authors:Jorge L. Porsani, Walter M. Filho, Vagner R. Elis, Fisseha Shimeles, Jo  o C. Dourado,Helyelson P. Moura
Affiliation:a Instituto de Astronomia, Geofísica e Ciências Atmosféricas da Universidade de São Paulo (IAG/USP)-Rua do Matão, 1226, Cidade Universitária 05508-090, São Paulo-SP, Brazil;b Instituto de Geociências e Ciências Exatas da Universidade Estadual Paulista, Campus de Rio Claro (IGCE/UNESP), Brazil
Abstract:This paper presents the results of the application of the Ground Penetrating Radar (GPR) method, or Georadar, in outlining a zone of contamination due to solid residues at the waste burial site of Rio Claro in the state of São Paulo, SE Brazil. A total of eight GPR profiles with 50- and 100-MHz antennae were surveyed. Six profiles were located within the landfill site and the remaining two were outside. The main objective of the GPR survey was to evaluate the side extension of contamination. A Vertical Electric Sounding (VES) survey was performed at four points within the site in order to investigate the vertical extent of the contamination plume and to define the bottom of the landfill. Two additional VESs were done outside the landfill with the purpose of determining the top of the ground water table and the geoelectric stratigraphy of the background. From the interpretation of the GPR profiles, it was possible to locate the top of the contamination plume and to infer that it was migrating laterally beyond the limits of the waste disposal site. This was observed along the profile situated close to the highway SP-127, which was about 20 m from the limit of the site. The signature of the contaminant appears as a discontinuous reflector that is believed to be a shallow ground water table. The discontinuity is marked by a shadow zone, which is characteristic of conductive contaminant residues. The contamination did not move far enough to reach a sugar cane plantation located at approximately 100 m from the border of the site. In the regions free from contamination, the ground water table was mapped at approximately 10 m of depth, and it was characterized by a strong and continuous reflector. The radar signal penetrated deep enough and enabled the identification of a second reflector at approximately 14 m deep, interpreted as the contact between the Rio Claro and the Corumbataí formations. The contact is marked by the presence of gravel characterized by ferruginous concretes, which cause the strong amplitude reflection in the GPR profile. Within the landfill site, the quantitative interpretation of the VES results showed the contamination zone. The base of the landfill varies between 11 and 15 m deep. Outside the landfill site, the VES results showed no indication of contamination and allowed the determination of the top of the ground water table and the contact between the Rio Claro and the Corumbataí formations. The results of GPR and VES showed a good agreement and the integrated interpretations were supported by local geology and information from several boreholes, about 17 m depth, on average. The bottom of the landfill reaches a maximum of 14.5 m depth.
Keywords:GPR   Georadar   VES   Contamination plume   Landfill   Rio Claro   Brazil
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号