首页 | 本学科首页   官方微博 | 高级检索  
     

两种尺寸蒸渗计测量实际蒸散差异性试验研究
引用本文:杨启国,杨兴国,张旭东,马鹏里,刘宏谊,李晓峰,党选发,孔令旺. 两种尺寸蒸渗计测量实际蒸散差异性试验研究[J]. 中国沙漠, 2017, 37(1): 167-174. DOI: 10.7522/j.issn.1000-694X.2015.00230
作者姓名:杨启国  杨兴国  张旭东  马鹏里  刘宏谊  李晓峰  党选发  孔令旺
作者单位:1. 中国气象局兰州干旱气象研究所 甘肃省干旱气候变化与减灾重点实验室/中国气象局干旱气候变化与减灾重点开放实验室, 甘肃 兰州 730020;2. 甘肃省气象局, 甘肃 兰州 730020;3. 甘肃省气象局 西北区域气候中心, 甘肃 兰州 730020;4. 甘肃省气象局 甘肃省气象信息与技术装备保障中心, 甘肃 兰州 730020
基金项目:国家公益性行业科研专项(GYHY201106043);国家自然科学基金项目(41175011)
摘    要:利用试验资料,对蒸散面积2 m2和4 m2两种尺寸蒸渗计测量蒸散量的差异及原因进行了研究。结果表明:2 m2蒸渗计与4 m2蒸渗计所测蒸散量具有很好的一致性,但2 m2蒸渗计所测蒸散量总体要略偏大,日蒸散量平均偏大4%,月蒸散量平均偏大10%,年蒸散量相对偏大5%;典型天气条件下,2 m2蒸渗计和4 m2蒸渗计所测蒸散量的日变化过程基本相同,小时蒸散量的差异表现为晴天时白天显著偏大、夜晚略有偏小,阴天时白天略偏大、夜晚较接近,雨天时白天、夜晚均非常接近的特征。晴天和阴天时,2 m2蒸渗计比4 m2蒸渗计测量日蒸散量分别偏大1.78 mm和0.12 mm,雨天时偏小0.11 mm;2 m2蒸渗计比4 m2蒸渗计测量蒸散量总体偏大的原因,主要是2 m2蒸渗计土壤温度显著高于4 m2蒸渗计和建造时间不同导致土体内部土壤湿度产生差异。

关 键 词:蒸渗计  蒸散量  土壤温度  土壤湿度  差异  
收稿时间:2015-08-19
修稿时间:2015-10-16

Difference of Actual Evapotranspiration Measured by Two Sizes Lysimeters
Yang Qiguo,Yang Xingguo,Zhang Xudong,Ma Pengli,Liu Hongyi,Li Xiaofeng,Dang Xuanfa,Kong Lingwang. Difference of Actual Evapotranspiration Measured by Two Sizes Lysimeters[J]. ournal of Desert Research, 2017, 37(1): 167-174. DOI: 10.7522/j.issn.1000-694X.2015.00230
Authors:Yang Qiguo  Yang Xingguo  Zhang Xudong  Ma Pengli  Liu Hongyi  Li Xiaofeng  Dang Xuanfa  Kong Lingwang
Abstract:Based on observed data, the difference of actual evapotranspiration and its causes are analyzed by comparing the lysimeter with evaporation area of 2 square meters ( referred to as 2 m2 lysimeter) and the lysimeter with evaporation area of 4 square meters (referred to as 4 m2 lysimeter). The results showed that measured evapotranspiration by two lysimeters was in good consistency, but the 2 m2 lysimeter's evapotranspiration was generally slightly larger than the 4 m2 lysimeter with 4% more for daily evapotranspiration, 10% more for monthly evapotranspiration, and 5% more for annual evapotranspiration; Under different types of synoptic conditions, the two lysimeter's evapotranspiration had a same diurnal variation. In sunny days and cloudy days, hourly evapotranspiration measured by the 2 m2 lysimeter was larger than 4 m2 lysimeter during the day, but slightly smaller or very close during the night. The hourly evapotranspiration measured by the two lysimeters was very close in the rainy days. The daily evapotranspiration measured by the 2 m2 lysimeter is 1.78 mm more than the 4 m2 lysimeter in the sunny days and 0.12 mm more in the cloudy days, respectively, and 0.11 mm less in the rainy days; Analysis the reasons for the 2 m2 lysimeter measured evapotranspiration is generally slightly larger than 4 m2 lysimeter, on the one hand, the soil temperature of 2 m2 lysimeter is significantly higher than that of 4 m2 lysimeter. On the other hand, it can be the different construction time of two sizes of lysimeters caused the soil moisture to produce difference,resulted in the difference of evapotranspiration.
Keywords:lysimeter  evapotranspiration  soil temperature  soil moisture  difference  
本文献已被 CNKI 等数据库收录!
点击此处可从《中国沙漠》浏览原始摘要信息
点击此处可从《中国沙漠》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号