Stabilization of the spectrum position in the main stellar spectrograph of the 6-m telescope of the Special Astrophysical Observatory of the Russian Academy of Sciences
Authors:G A Chountonov  I D Najdenov
Institution:(1) Special Astrophysical Observatory, Russian Academy of Sciences, Nizhnij Arkhyz, 369167, Russia
Abstract:New results on the stability analysis study of the Main Stellar Spectrograph of the 6-m telescope of the Special Astrophysical Observatory of the Russian Academy of Sciences when it operated jointly with the CCD detection system on a laboratory source are reported. The spectrum is found to drift along the dispersion direction for several tenths of a pixel (several hundredths of angstrom) over a one-hour time scale. To prevent this drift (i.e., the spectrum shift)—a plane parallel glass plate is mounted; tilt angle of this plate varies as a function of the misalignment between the current and reference spectra of a hollow-cathode tube laboratory source. Operation of the spectrum stabilizer is described. The correction time is of about 1 minute, allowing the position of the spectrum to be maintained to within ±0.0006Å.