Pushover and nonlinear time history analysis evaluation of a RC building collapsed during the Van (Turkey) earthquake on October 23, 2011 |
| |
Authors: | Özlem Çavdar Alemdar Bayraktar |
| |
Affiliation: | 1. Department of Civil Engineering, Gümü?hane University, 29000, Gümü?hane, Turkey 2. Department of Civil Engineering, Karadeniz Technical University, 61080, Trabzon, Turkey
|
| |
Abstract: | The nonlinear seismic behavior of a collapsed reinforced concrete (RC) residential building in the city of Van in Turkey is investigated by the static pushover and nonlinear time history analyses. The selected RC structure was designed according to the 1975 version of Turkish Earthquake Code (TEC-1975). The building had experienced heavy damage, and it was demolished in the Van earthquake on October 23, 2011. The 2007 version of Turkish Earthquake Code (TEC-2007) is considered for the assessing seismic performance evaluation of the selected RC building. The RC structure presents collapse performance level under the earthquake loads. Besides, the analytical solutions show that different performance levels for the sections are obtained from the pushover and nonlinear time history methods. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|