Three-dimensional electrical resistivity model of a nuclear waste disposal site
Institution:1. MOE Key Laboratory of Soft Soils and Geoenvironmental Engineering, College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, China;2. Institut für Meteorologie und Geophysik (IMGW), University of Vienna, Vienna, Austria;3. Department of Geology, University of Kansas, Lawrence, KS 66045, USA;4. Department of Civil Engineering and Construction, Georgia Southern University, 1332 Southern Drive, Statesboro, GA 30458, USA;5. College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, China;1. Engineering Geology, Lund University, P.O. Box 118, SE-22100 Lund, Sweden;2. Department of Geoscience, Aarhus University, C.F.Møllers Allé 4, Building 1120, 8000 Aarhus C, Denmark;1. SCCER-SoE, ETH Zurich, Zurich, Switzerland;2. Department of Geoscience, Aarhus University, Aarhus, Denmark;3. Department of Civil Engineering, Technical University of Denmark, Lyngby, Denmark;4. Center for Permafrost (CENPERM), Department of Geosciences and Natural Resource Management, University of Copenhagen, Øster Voldgade 10, DK-1350 Copenhagen K., Denmark;1. Departamento de Ciencias de la Tierra, Universidad de Zaragoza, Edificio Geológicas, C/. Pedro Cerbuna 12, 50009 Zaragoza, Spain;2. Departamento de Geología, Universidad Autónoma de Barcelona, Barcelona, Spain;3. Àrea de Geodinàmica Externa i Geomorfologia, Universitat de Girona, Girona, Spain;4. Geo-Haz Consulting Inc., CO, USA;5. Universidad Estatal de Bolivar, Guaranda, Ecuador;1. Politecnico di Torino, C.so Duca degli Abruzzi, 24, I-10129 Torino, Italy;2. CNR-IGG, National Research Council of Italy, Via Moruzzi,1, 56124 Pisa, Italy
Abstract:A three-dimensional (3D) modeling study was completed on a very large electrical resistivity survey conducted at a nuclear waste site in eastern Washington. The acquisition included 47 pole–pole two-dimensional (2D) resistivity profiles collected along parallel and orthogonal lines over an area of 850 m × 570 m. The data were geo-referenced and inverted using EarthImager3D (EI3D). EI3D runs on a Microsoft 32-bit operating system (e.g. WIN-2K, XP) with a maximum usable memory of 2 GB. The memory limits the size of the domain for the inversion model to 200 m × 200 m, based on the survey electrode density. Therefore, a series of increasing overlapping models were run to evaluate the effectiveness of dividing the survey area into smaller subdomains. The results of the smaller subdomains were compared to the inversion results of a single domain over a larger area using an upgraded form of EI3D that incorporates multi-processing capabilities and 32 GB of RAM memory. The contours from the smaller subdomains showed discontinuity at the boundaries between the adjacent models, which do not match the hydrogeologic expectations given the nature of disposal at the site. At several boundaries, the contours of the low resistivity areas close, leaving the appearance of disconnected plumes or open contours at boundaries are not met with a continuance of the low resistivity plume into the adjacent subdomain. The model results of the single large domain show a continuous monolithic plume within the central and western portion of the site, directly beneath the elongated trenches. It is recommended that where possible, the domain not be subdivided, but instead include as much of the domain as possible given the memory of available computing resources.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号