首页 | 本学科首页   官方微博 | 高级检索  
     


Analysis of Power Supply Interference of Geomagnetic Second Data Observation-Take Changli Seismic Station as An Example
Authors:TONG Xin  ZHOU Jianqing  LIU Zhe  ZHANG Guoling  GUO Jianfang
Affiliation:Qinhuangdao Central Station, Hebei Earthquake Agency, Qinhuangdao 066100, China;Hebei Earthquake Agency, Shijiazhuang 050021, China
Abstract:This paper analyzes two types of power supply interference encountered in the observation of geomagnetic second data: the HVDC interference and the discharge interference of electrified railway. By taking the FGM fluxgate magnetometer of Changli Seismic Station as the research object,we analyze interference characteristics and conduct intensive observational experiment of electrified railway interference.Finally,several conclusions are obtained:(1) HVDC interference is closely related to the changes in the current system of the interference source,such as current size,distance or orientation of the interference source. Although the characteristics of each change are not the same, the main changes are variable.(2) The discharge phenomenon caused by the contact of the pantograph system or other reasons during the operation of the electrified railway is a factor that may cause random small interference in the geomagnetic second data at Changli Seismic Station. This study explains similar phenomena discovered in previous years and meanwhile correct previous misjudgments including unstable working systems,unstable power supply,and occasional sudden jumps that are considered to be discrete.
Keywords:Geomagnetism  Electrified railway  Interference
本文献已被 CNKI 等数据库收录!
点击此处可从《中国地震研究》浏览原始摘要信息
点击此处可从《中国地震研究》下载全文