Polarographische Bestimmung von Schwermetallen im Klärschlamm |
| |
Authors: | J Malý M Bareov |
| |
Institution: | J. Malý,M. Bare?ová |
| |
Abstract: | The differential-pulse polarography (DPP) and the stripping voltametry (SV) are investigated in detail with respect to their suitability for the quantitative detection of individual traces of heavy metals in sewage sludge. The results are checked on the basis of AAS analyses and by the standard-addition method. From the hydrochloric-acid extracts of fused sludge samples down to 1 μg/l can be detected by the SV, whereas the DPP reaches a sensitivity of 100 μg/l. The following basic electrolytes are used: Zn: 2 … 3 mol/l H3PO4; Cu: 0.4 mol/l K2CO3, 0.2 mol/l Na-K-tartrate, 0.1 mol/l HCl; Ni: 1 mol/l NH4OH, 1 mol/l NH4Cl, 25 ml/l triethylamine; Pb and Cd: 0.1 … 0.2 mol/l HCl. |
| |
Keywords: | |
|
|