Design and installation of a combined automatic tensiometer-piezometer system |
| |
Authors: | M. G. Anderson M. J. Kemp D. M. Lloyd A. Othman |
| |
Abstract: | Currently available systems for monitoring both negative and positive pore pressures have certain restrictions as to their use. A system design is described that seeks to overcome some of the potentially more restrictive elements insofar as site investigations in tropical slopes are concerned. In particular, the system uses an integrated approach to both pore pressure and ancillary (e.g. raingauge) monitoring. Initial trials of the instrumentation suggest its suitability for pore pressure recording where high temporal resolution is needed in both negative and positive pressures. |
| |
Keywords: | Pore pressures Tensiometer Piezometer Data-logging system |
|