首页 | 本学科首页   官方微博 | 高级检索  
     

考虑辐射阻尼的土-结构相互作用体系等效输入
引用本文:雷素素,高永涛,潘旦光. 考虑辐射阻尼的土-结构相互作用体系等效输入[J]. 岩土力学, 2016, 37(Z1): 583-590. DOI: 10.16285/j.rsm.2016.S1.076
作者姓名:雷素素  高永涛  潘旦光
作者单位:1. 北京科技大学 土木与环境工程学院,北京 10083;2. 同济大学 土木工程防灾国家重点实验室,上海 200092
基金项目:土木工程防灾国家重点实验室开放基金(No. SLDRCE15-01)。
摘    要:为考虑土-结构相互作用对输入地震波的影响,基于两步法思想,建立了考虑辐射阻尼效应的等效输入地震波。在该种方法中,将单自由度体系的基础地震反应为上部结构的输入,然后用状态空间法计算考虑土-结构相互作用后体系阻尼比的变换情况,用以修正上部结构的阻尼系数,从而利用刚性基础的反应近似计算土-结构相互作用的影响。对一个单自由度体系和一个5层框架结构进行计算分析,算例分析表明,直接利用自由场的地震波或基岩波作为上部结构的输入,计算误差甚至超过100%,而两步法可使体系的计算误差小于10%,采用修正阻尼系数的两步法,误差将小于5%,满足工程需要。

关 键 词:辐射阻尼  土-结构相互作用  等效输入  地震反应  
收稿时间:2015-10-29

Equivalent input of soil-structure interaction system considering radiation damping
LEI Su-su,GAO Yong-tao,PAN Dan-guang. Equivalent input of soil-structure interaction system considering radiation damping[J]. Rock and Soil Mechanics, 2016, 37(Z1): 583-590. DOI: 10.16285/j.rsm.2016.S1.076
Authors:LEI Su-su  GAO Yong-tao  PAN Dan-guang
Affiliation:1.School of Civil and Environmental Engineering, University of Science and Technology Beijing, Beijing 100083, China; 2. State Key Laboratory for Disaster Reduction in Civil Engineering, Tongji University, Shanghai 200092, China
Abstract:Taking account of soil-structure interaction on seismic wave input, based on the theory of a two-step method, equivalent seismic wave input considering radiation damping effects is established. Firstly, the base response of single degree of freedom system is considered as the input of superstructure; and then damping ratio of the system is calculated by the state-space method considering soil-structure interaction, which is used to modify the damping coefficients of superstructure; thus the impact of soil-structure interaction is approximately calculated from the response of rigid foundation. Subsequently, a single degree of freedom system and a five-story frame structure are analyzed; numerical examples show that the calculation errors even exceed 100%; while directly taking seismic wave of free field and bedrock as the input of superstructure. However, the calculation errors of the two-step method are less than 10%; furthermore, the calculation errors will be less than 5% adopting the modified damping two-step method, which can satisfy the requirements of engineering.
Keywords:radiation damping   soil-structure interaction  equivalent input  seismic response  
本文献已被 CNKI 等数据库收录!
点击此处可从《岩土力学》浏览原始摘要信息
点击此处可从《岩土力学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏