Optimized Design of Spacer in Electrodialyzer Using CFD Simulation Method
Authors:Yuxiang Jia  Chunsheng Yan  Lijun Chen  Yangdong Hu
Institution:1.Key Laboratory of Marine Chemistry Theory and Technology,Ministry of Education,Qingdao,China;2.College of Chemistry and Chemical Engineering,Ocean University of China,Qingdao,China
Abstract:In this study, the effects of length-width ratio and diversion trench of the spacer on the fluid flow behavior in an electrodialyzer have been investigated through CFD simulation method. The relevant information, including the pressure drop, velocity vector distribution and shear stress distribution, demonstrates the importance of optimized design of the spacer in an electrodialysis process. The results show width of the diversion trench has a great effect on the fluid flow compared with length. Increase of the diversion trench width could strength the fluid flow, but also increase the pressure drop. Secondly, the dead zone of the fluid flow decreases with increase of length-width ratio of the spacer, but the pressure drop increases with the increase of length-width ratio of the spacer. So the appropriate length-width ratio of the space should be moderate.
Keywords:
本文献已被 CNKI SpringerLink 等数据库收录!