Emission quantification of refrigerant CFCs,HCFCs and HFCs in megacity Lahore (Pakistan) and contributed ODPs and GWPs
Authors:Zia Ul-Haq  Muhammad Ali  Syeda Adila Batool  Salman Tariq  Zarmina Qayyum
Abstract:An integrated assessment of emissions of some important refrigerant ozone depleting substances (ODSs) (CFC-11, CFC-12, HCFC-141b and HFC-134a) and their contributed ozone depletion potentials (ODPs) and global warming potentials (GWPs) have been made in the megacity Lahore (Pakistan) for the period from 2005 to 2013. During the production of 6.488 million refrigerator units, the cumulative estimated emissions of CFC-11, CFC-12, HCFC-141b and HFC-134a were 129.7, 6.8, 1257 and 104 mega grams (1 Mg = 106 grams). The estimated GWP (CO2-eq) and ODP (CFC 11-eq) associated with production phase emissions of these four gases were 616.07, 73.52, 910.96, and 87.36 kilotonnes, and 129.7, 6.8, 139.4, and 0 tonnes, respectively. ODP of HFC-134a is considered to be zero. In addition, the repair and maintenance of 81.2 thousand units resulted in 10.8 Mg emissions of CFC-12 with 10.8 tonnes ODP(CFC 11-eq) and 117,802 tonnes GWP (CO2-eq) that were higher than the HFC-134a emissions recorded at 4.3 Mg causing 4563 tonnes GWP(CO2-eq). A decrease in ODP (CFC 11-eq) and GWP (CO2-eq) at the rate of ?8.3% and ?8.2% per year is observed to be contributed by all the selected ODSs during the study period.