首页 | 本学科首页   官方微博 | 高级检索  
     

三孔较差视宁度监视仪及试观测报告
引用本文:岑学奋,许骏,谭徽松. 三孔较差视宁度监视仪及试观测报告[J]. 天文研究与技术, 1996, 0(1)
作者姓名:岑学奋  许骏  谭徽松
作者单位:中国科学院云南天文台
摘    要:本文介绍了云南天文台研制的三孔较差视宁度监视仪,统计了1994年3月至7月期间的试观测情况,及仪器定标和数据处理结果。

关 键 词:视宁度监视仪,观测,定标

The Differential Image Motion Monitor with Three Sub-aperture at Yunnan Observatory
Qin Xuefeng, XuJun, Tan Huisong. The Differential Image Motion Monitor with Three Sub-aperture at Yunnan Observatory[J]. Astronomical Research & Technology, 1996, 0(1)
Authors:Qin Xuefeng   XuJun   Tan Huisong
Abstract:The Differential Image Motion Monitor (DIMM) with three sub-aperture was developed at Yunnan Observatory.The DIMM is attached to a 35cm telescope with f/ 15. The apertures are 23cm or 16.3cm apart and have a diameter of 10cm. Two 20" prism wedges are positioned over two of the three sub-apertures to separate two images from the other one by 10.4" at the focal plane.The monitor was first tasted the seeing near the dome of 1m telescope at Yunnan Observatory on Apr.8, 1994, and since then 1770 ro at 16 nights have been recorded. The average ro measured is 12cm, and has good correlation with diffraction ring observation.On May 24 and 25, 1994, Full Width at Half Maximum (FWHM) of stellar images was measured on 20s' exposure time in the direct CCD imaging mode with the 1m telescope. The mean FWHM of the images is 1.15",and the seeing measured by DIMM is 0.906".
Keywords:DIMM Observation Calibration
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号