首页 | 本学科首页   官方微博 | 高级检索  
     


On the individual calibration of hailpads
Authors:Covadonga Palencia   Claude Berthet   Marta Massot   Amaya Castro   Jean Dessens  Roberto Fraile  
Affiliation:aDepartamento de Física, Universidad de León, Spain;bANELFA, Toulouse, France;cADV de les Terres de Ponent, Lleida, Spain
Abstract:This paper is a comparative study between the two most common hailpad calibration systems: one annual calibration of a whole consignment of material, and the individual calibration of each plate after a hailfall. Individual calibration attempts to minimize errors due to differences in sensitivity to the impact of hailstones between plates from the same consignment, or due to differences in the inking process before the actual measurement.The comparison was carried out using calibration data from the past few years in the hailpad network in south-western France, and data from an individual calibration process on material provided by the hailpad network in Lleida (Spain). The same type of material was used in the two cases.The results confirm that the error in measuring hailstone sizes is smaller in the case of an individual calibration of hailpads than when one single calibration process was carried out for a whole consignment. The former is approximately 80% of the latter. However, this error could have been higher if it had not been the same person carrying out the single calibration process and the measuring of the dents: it has been found that differences in the inking process may account for up to 20% of the error in the case of small hailstones. Calibration errors affecting other variables, e.g. energy or parameter λ of the exponential size distribution are generally higher (5% and 18%, respectively) than errors due to the spatial variability of the hailstones. However, the calibration method does not influence the maximum size, since the relative error attributed to the spatial variability is about 8 times the calibration error.In conclusion, if errors in determining energy or parameter λ are to be reduced to a minimum, it is highly advisable to be consistent in applying the measuring procedure (if possible with the same person carrying out the measurements all the time), and even to use individual calibration on each plate, always bearing in mind that technicians have to be trained appropriately in order to achieve the highest possible degree of uniformity.
Keywords:Hailpad   Calibration   Hailstone size   Measurement error
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号