首页 | 本学科首页   官方微博 | 高级检索  
     

64层CT回顾性心电门控低剂量冠脉成像的临床研究
引用本文:高洁, 张雪峰. 64层CT回顾性心电门控低剂量冠脉成像的临床研究[J]. CT理论与应用研究, 2012, 21(1): 67-72.
作者姓名:高洁  张雪峰
作者单位:1.内蒙古自治区人民医院介入放射科, 呼和浩特 010020
摘    要:目的:通过比较图像质量与辐射剂量,评价64层螺旋CT低剂量回顾性心电门控冠脉成像技术临床应用的可行性。方法:选取拟行CT冠状动脉造影的患者80例(心率小于65次/min,心率波动范围小于5次/min),所选患者分为两组,分别进行低剂量回顾性心电门控(40例,开启ECG管电流调制技术,70%~80%期相满电流输出)及常规回顾性心电门控(40例,35%~80%期相满电流输出)CT冠脉造影,依据患者体质量指数选择管电流(400~800mA),管电压120kV。比较两组的辐射剂量及图像质量。P<0.05认为差异具有统计学意义。结果:低剂量回顾门控组与常规回顾门控组图像质量差异无统计学意义(Z=-4.78,P=0.23)。低剂量回顾门控组CTCA辐射剂量平均(13.76±2.38)mSv,常规回顾门控组CTCA辐射剂量平均(20.06±3.35)mSv,差异有统计学意义(t=-8.39,P=0.00),使用低剂量回顾门控降低了31.4%的辐射剂量。结论:低心率患者行回顾门控CTCA通过修改ECG管电流调制技术参数得到的图像质量与常规回顾门控CTCA无差别,而辐射剂量显著减低。

关 键 词:X线计算机  体层摄影术  冠状动脉  辐射剂量  心电门控
收稿时间:2011-09-04

Low Dose 64-slice CT Coronary Angiography with Retrospective ECG Gating: A Clinical Study
GAO Jie, ZHANG Xue-feng. Low Dose 64-slice CT Coronary Angiography with Retrospective ECG Gating: A Clinical Study[J]. CT Theory and Applications, 2012, 21(1): 67-72.
Authors:GAO Jie  ZHANG Xue-feng
Affiliation:1.Department of Radiology, Inner Mongolia Peoole's Hospita, Hohhot 010020, China
Abstract:Objective: To compare image quality and radiation dose for coronary artery computed tomographic angiograms(CTA) with retrospectively gated helical(RGH) CT technique in two methods using 64-slice spiral CT.Methods: 80 patients with low heart rate enrolled in this study were randomly divided into two groups.The low dose RGH group was 40 patients with average body mass index(BMI) 27.06 using ECG modulation technique(full mA on 70%~80% of the R-R interval and the lowest mA on rest of phases).The traditional RGH group was 40 patients with BMI 25.66 using ECG modulation technique(full mA on 35%~80% of the R-R interval and the lowest mA on rest of phases).Two groups were evaluated for image quality(each coronary artery segment,5-point scale) and radiation dose and compared with image quality score and radiation dose by Mann-Whitney U-test and unpaired t-test.A p value below 0.05 was considered statistically significant.Results: The mean effective dose for the low dose RGH group was 13.76 mSv;this represents a 31.40% reduction as compared with that for the traditional RGH group(mean,20.06 mSv;t =-8.391,P = 0.00).The mean image quality score was 4.05 for images obtained with low dose ECG modulation technique versus 4.19 for images obtained with traditional ECG modulation technique(Z =-4.78,P = 0.23).Conclusion: RGH coronary CT angiography using ECG modulation technique(full mA on 70%~80% of the R-R interval and the lowest mA on rest of phases) could offer assessable image quality and substantially reduced effective radiation dose compared with traditional RGH coronary CT angiography at low heart rate.
Keywords:X-ray computed  tomography  coronary artery  radiation dose  ECG-gating
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《CT理论与应用研究》浏览原始摘要信息
点击此处可从《CT理论与应用研究》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号