首页 | 本学科首页   官方微博 | 高级检索  
     

基于ADTD资料的浙江地区多回击地闪特征分析
引用本文:崔雪东,张卫斌,顾媛,田德宝. 基于ADTD资料的浙江地区多回击地闪特征分析[J]. 气象科技, 2021, 49(3): 491-497
作者姓名:崔雪东  张卫斌  顾媛  田德宝
作者单位:浙江省气象安全技术中心,杭州310008;浙江省嘉兴市气象局,嘉兴314050
基金项目:浙江省气象局一般项目(2019YB09)资助
摘    要:利用2007-2018年浙江省ADTD闪电定位资料,分析了该地区多回击地闪分布及相关参数特征.结果表明:浙江省多回击地闪占总地闪的26.74%,其中正闪以单回击地闪为主;正、负闪平均回击数分别为1.04次和1.65次,最大回击数分别为5次和21次.回击数和地闪数存在较为一致的年际变化,正、负多回击地闪日变化分别呈多峰和...

关 键 词:地闪  回击  电流强度  间隔时间
收稿时间:2020-05-28
修稿时间:2020-12-29

Characteristic Analysis of Multi-return Strokes of Cloud-to-Ground Lightning in Zhejiang Based on ADTD Data
CUI Xuedong,ZHANG Weibin,GU Yuan,TIAN Debao. Characteristic Analysis of Multi-return Strokes of Cloud-to-Ground Lightning in Zhejiang Based on ADTD Data[J]. Meteorological Science and Technology, 2021, 49(3): 491-497
Authors:CUI Xuedong  ZHANG Weibin  GU Yuan  TIAN Debao
Affiliation:Zhejiang Meteorological Safety Technology Center, Hangzhou 310008; Jiaxing Meteorological Service, Zhejiang, Jiaxing 314050
Abstract:Based on the lightning location data of ADTD in Zhejiang Province from 2007 to 2018, the distribution and related parameters of multiple return strokes of cloud to ground (CG) lightning are analyzed. The results show that the number of multiple return stroke flashes accounts for 26.79% of the total CG number. The positive flashes are dominated by single return stroke CG lightning flashes. The mean stroke number of positive CG and negative CG is 1.04 and 1.65, and the maximum stroke number is 5 and 21, respectively. The inter annul variation features of multiple stroke CG lightning flashes and total CG lightning flashes are consistent. The daily changes of positive CG and negative CG show multimodal and unimodal distributions, respectively. The arithmetic mean current intensity of the positive multiple stroke lightning is 72.06 kA, and that of the negative is -36.89 kA. The average current for CG flashes of particular multiplicity has a tendency of decreasing with the stroke order. Furthermore, about 40% of multiple stroke CG flashes have at least one subsequent stroke, with the initial peak electric field stronger than that of the first return stroke. The current intensities of the first return stroke and flowing stroke of CG show a log normal distribution, in which the stroke frequency is the highest when the current intensity is from 15 kA to 45 kA. The arithmetic mean interval stroke of positive CG lightning is 125.47 ms, and the negative is 138.14 ms. The geometric mean interval stroke of positive CG lightning is 56.73 ms, and the negative is 98.95 ms. The interval of stroke lightning also shows a log normal distribution. The mean interval has a tendency of decreasing with the stroke order. The distribution of interval distance between first return stroke and flowing stroke shows a quasi normal distribution, and the strokes mostly occur within the range of 1 km.
Keywords:cloud to ground lightning flash   return stroke   current intensity   return strokes interval
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《气象科技》浏览原始摘要信息
点击此处可从《气象科技》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号