绝对重力仪双采样过零检测中量化噪声的影响分析
引用本文:胡明,钟敏.绝对重力仪双采样过零检测中量化噪声的影响分析[J].大地测量与地球动力学,2017,37(9):973-976.
作者姓名:胡明  钟敏
摘    要:利用高速采集系统完整记录绝对重力仪棱镜自由下落的干涉条纹波形,能够获取更多的重力信息。详细讨论了干涉条纹电压信号幅值与ADC相关参数,如等效位数、参考电压、采样频率等对重力测量的影响。结果表明,通过参数优化设计可以将ADC量化的影响限制在0.01 μGal。

关 键 词:数字化干涉条纹  量化噪声  绝对重力仪  双采样过零检测  

Quantizing Noise Impact Analysis of the Two-Sample Zero-Crossing Methodin the Free Fall Absolute Gravimeter
HU Ming,ZHONG Min.Quantizing Noise Impact Analysis of the Two-Sample Zero-Crossing Methodin the Free Fall Absolute Gravimeter[J].Journal of Geodesy and Geodynamics,2017,37(9):973-976.
Authors:HU Ming  ZHONG Min
Abstract:High speed ADC is employed in the free fall absolute gravimeter to record the integral fringe waveform, acquiring more information about local gravity. We discuss variations in gravity acceleration due to some parameters such as amplitude of the fringe voltage signal, ADC bits, reference voltage, and sampling frequency. The analysis shows that the gravity error caused by ADC quantization could be limited to 0.01 μGal by parameters optimization.
Keywords:digital fringes  quantizing noise  absolute gravimeter  two-sample zero-crossing  