一次自动气象站温度数据干扰的处理过程
引用本文:王毅军,张朝明,李延晖,王锴.一次自动气象站温度数据干扰的处理过程[J].气象科技,2017,45(2):276-280.
作者姓名:王毅军  张朝明  李延晖  王锴
作者单位:山西省大气探测技术保障中心,太原 030002,山西省大气探测技术保障中心,太原 030002,山西省大气探测技术保障中心,太原 030002,山西省大气探测技术保障中心,太原 030002
摘    要:针对太原北郊DYYZII型自动气象站温度信号干扰的故障,结合该型自动站的信号传输方式和结构类型、设备接地网的分布形式、作用原理以及接地电阻测量值、外部环境对系统的影响程度评估等进行了综合分析。在常规处理方法不能彻底解决问题的情况下,运用多学科理论知识,对接地引线连接中由于金属氧化物作用对实际接地效果产生影响等方面的原因进行了详细的分析,同时提出了"接地电阻值符合要求不一定等于实际接地效果符合要求"的观点。在最终故障处理、验证过程中证明了金属氧化物对接地线的导电性能有直接的影响,为今后处理自动气象站温度信号干扰问题提供了一种新的分析思路和解决方法。

关 键 词:自动气象站  温度  信号干扰  金属氧化物  接地电阻值  接地效果
收稿时间:2016/4/19 0:00:00
修稿时间:2016/10/8 0:00:00

A Solution of AWS Data Interference
Wang Yijun,Zhang Chaoming,Li Yanhui and Wang Kai.A Solution of AWS Data Interference[J].Meteorological Science and Technology,2017,45(2):276-280.
Authors:Wang Yijun  Zhang Chaoming  Li Yanhui and Wang Kai
Institution:Atmospheric Sounding Technology Assurance Center of Shanxi Province, Taiyuan 030002,Atmospheric Sounding Technology Assurance Center of Shanxi Province, Taiyuan 030002,Atmospheric Sounding Technology Assurance Center of Shanxi Province, Taiyuan 030002 and Atmospheric Sounding Technology Assurance Center of Shanxi Province, Taiyuan 030002
Abstract:Aiming at the troubleshooting of AWS temperature signal interference in the north suburbs of Taiyuan, a detailed analysis is made of the signal transmission mode and structure of the DYYZII automatic weather station,the distribution,working principles of the equipment grounding grid,and earthing resistance measurements, as well as the influence of metal oxides on actual grounding effectiveness in the grounding wire and the origin of the temperature sensor signal interference. The earthing resistance correspondence between requirements and actual grounding effect is discussed,and it is point out that meeting the requirements of grounding resistance values is not necessarily equal to meeting the requirements of the actual grounding effect. The troubleshooting and verification process indicates that there is direct impact of metal oxides on the conductivity of the grounding wire,which provides an analytical solution for future AWS temperature signal interference researches.
Keywords:signal interference  metal oxide  grounding resistance  earthing effect