Resupply mechanism to a contaminated aquifer: A laboratory study of U(VI) desorption from capillary fringe sediments
Authors:Wooyong Um  Chongxuan Liu  Dean A Moore  Kenton A Rod
Institution:Pacific Northwest National Laboratory, Richland, WA 99354, USA
Abstract:Contaminated capillary fringe sediments are believed to function as long-term source of U(VI) to Hanford’s 300 Area groundwater uranium plume that discharges to the Columbia River. The deep vadose zone at this site experiences seasonal water table elevation and water compositional changes in response to Columbia River stage. Batch and column desorption experiments of U(VI) were performed on two mildly contaminated sediments from this system that vary in hydrologic position to ascertain their U(VI) release behavior and factors controlling it. Solid phase characterization of the sediments was performed to identify mineralogic and chemical factors controlling U(VI) desorption. Low adsorbed U(VI) concentrations prevented spectroscopic analysis. The desorption behavior of U(VI) was different for the two sediments in spite of similar chemical and textural characteristics, and non-carbonate mineralogy. Adsorption strength and sorbed U(VI) lability was higher in the near-river sediment. The inland sediment displayed low sorbed U(VI) lability (∼10%) and measurable solid-phase carbonate content. Kinetic desorption was observed that was attributed to regeneration of labile U(VI) in the near river sediment, and carbonate mineral dissolution in the inland sediment. The desorption reaction was best described as an equilibrium surface complexation reaction. The noted differences in desorption behavior appear to result from U(VI) contamination and hydrologic history, as well as sediment carbonate content. Insights are provided on the dynamic adsorption/desorption behavior of contaminants in linked groundwater-river systems.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号