首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A calibration and temperature correction procedure for the water‐content reflectometer
Authors:Andrew W Western  Mark S Seyfried
Abstract:Calibration is required for most soil moisture sensors if accurate measurements are to be obtained. This can be time consuming and costly, especially if field calibration is undertaken, but can be facilitated by a good understanding of the behaviour of the particular sensor being calibrated. We develop generalized temperature correction and soil water calibration relationships for Campbell Scientific CS615 water‐content reflectometer sensors. The temperature correction is estimated as a function of the raw sensor measurement. The calibration relationship requires one soil‐related parameter to be set. These relationships facilitate field calibration of these sensors to acceptable accuracies with only a small number of samples. Copyright © 2005 John Wiley & Sons, Ltd.
Keywords:soil moisture  water content reflectometer  calibration
设为首页 | 免责声明 | 关于勤云 | 加入收藏