The role of prior model calibration on predictions with ensemble Kalman filter
Authors:Huber E  Hendricks-Franssen H J  Kaiser H P  Stauffer F
Institution:Institute of Environmental Engineering, ETH Zurich, Wolfgang-Pauli-Strasse 15, 8093 Zurich, Switzerland.
Abstract:This paper, based on a real world case study (Limmat aquifer, Switzerland), compares inverse groundwater flow models calibrated with specified numbers of monitoring head locations. These models are updated in real time with the ensemble Kalman filter (EnKF) and the prediction improvement is assessed in relation to the amount of monitoring locations used for calibration and updating. The prediction errors of the models calibrated in transient state are smaller if the amount of monitoring locations used for the calibration is larger. For highly dynamic groundwater flow systems a transient calibration is recommended as a model calibrated in steady state can lead to worse results than a noncalibrated model with a well-chosen uniform conductivity. The model predictions can be improved further with the assimilation of new measurement data from on-line sensors with the EnKF. Within all the studied models the reduction of 1-day hydraulic head prediction error (in terms of mean absolute error MAE]) with EnKF lies between 31% (assimilation of head data from 5 locations) and 72% (assimilation of head data from 85 locations). The largest prediction improvements are expected for models that were calibrated with only a limited amount of historical information. It is worthwhile to update the model even with few monitoring locations as it seems that the error reduction with EnKF decreases exponentially with the amount of monitoring locations used. These results prove the feasibility of data assimilation with EnKF also for a real world case and show that improved predictions of groundwater levels can be obtained.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号