Determination of discharge coefficients for a cross-flooding duct |
| |
Authors: | Mikael Stening,Juha Jä rvelä ,Pekka Ruponen,Risto Jalonen |
| |
Affiliation: | a Water Engineering Group, Aalto University School of Engineering, P.O. Box 15300, FI-00076 Aalto, Finland b Napa Ltd., Tammasaarenkatu 3, FI-00180 Helsinki, Finland c Marine Technology Group, Aalto University School of Engineering, P.O. Box 15300, FI-00076 Aalto, Finland |
| |
Abstract: | Cross-flooding ducts are used to equalize asymmetric flooding and, thus, to decrease the heel angle of a ship in an emergency. The present design guidelines for cross-flooding arrangements involve uncertainties associated with the effect of variable structural factors. In this study, scale model experiments were carried out to determine discharge coefficients of a typical cross-duct, with a focus on the effect of structural components such as the girders, stiffeners, and web frame. Flow conditions and configuration of the components were varied in the experiments. The structural stiffeners in the cross-duct were found to notably increase the discharge coefficient whereas the effects of the web frame and the inclination of the duct at an angle of 7° were negligible. The experimentally obtained discharge coefficient values for the cross-duct were considerably lower than the corresponding values computed according to the generally used guidelines of the IMO Resolution MSC.245(83). This indicates that the geometrical properties of the girders in the cross-ducts need to be properly addressed to avoid overestimating the discharge coefficients. Overall, the experimental results formed an indispensable dataset for the validation and further development of CFD approaches. |
| |
Keywords: | Ship damage stability Asymmetric flooding Cross-duct Discharge coefficient Pressure loss Experiments Girder Stiffener Web frame |
本文献已被 ScienceDirect 等数据库收录! |
|