首页 | 本学科首页   官方微博 | 高级检索  
     

AlphaGUARD与FD-125测氡仪的对比观测研究
引用本文:姚玉霞,任宏微,郭丽爽,王康,苗在鹏,叶媛媛,马荣荣. AlphaGUARD与FD-125测氡仪的对比观测研究[J]. 震灾防御技术, 2016, 11(3): 641-646
作者姓名:姚玉霞  任宏微  郭丽爽  王康  苗在鹏  叶媛媛  马荣荣
作者单位:甘肃省地震局平凉中心地震台,平凉 744000,中国地震局地壳应力研究所地壳动力学重点实验室,北京 100085,中国地震局地壳应力研究所地壳动力学重点实验室,北京 100085,甘肃省地震局平凉中心地震台,平凉 744000,甘肃省地震局平凉中心地震台,平凉 744000,甘肃省地震局陇南中心地震台,陇南 746000,甘肃省地震局平凉中心地震台,平凉 744000
基金项目:地震行业科研专项(201308006);中国地震局三结合项目(15280X)
摘    要:本文用AlphaGUARD测氡仪进行真空状态下静置时间与氡浓度关系的实验,以总结AlphaGUARD测氡仪测试氡值的最佳稳定时间段及氡值变化是否符合氡衰变规律;通过对平行样品的观测,分析了AlphaGUARD测氡仪与FD-125测氡仪的一致性问题。结果表明,在静置时间70min以内,氡值变化比较稳定,70min之后氡观测值逐渐降低,基本符合氡放射性衰变规律:AlphaGUARD测氡仪与FD-125测氡仪结果具有一定偏差,平均相对偏差小于约10%。据推测可能是两个仪器的系统测试误差造成的,另外FD-125测氡仪自身存在校准氡源活度与样品浓度差距过大而导致测试结果偏离等缺点。以上实验结果为AlphaGUARD测氡仪在地震系统的推广应用积累了经验。

关 键 词:AlphaGUARD测氡仪;FD-125测氡仪;静置时间;对比观测
收稿时间:2015-10-26

Comparison between AlphaGUARD and FD-125 Radon detectors
Yao Yuxi,Ren Hongwei,Guo Lishuang,Wang Kang,Miao Zaipeng,Ye Yuanyuan and Ma Rongrong. Comparison between AlphaGUARD and FD-125 Radon detectors[J]. Technology for Earthquake Disaster Prevention, 2016, 11(3): 641-646
Authors:Yao Yuxi  Ren Hongwei  Guo Lishuang  Wang Kang  Miao Zaipeng  Ye Yuanyuan  Ma Rongrong
Affiliation:Pingliang Central Seismic Station of Earthquake Administration of Gansu Province, Pingliang 744000, Gamsu, China,Institute of Crustal Dynamics, CEA, Beijing 100085, China,Institute of Crustal Dynamics, CEA, Beijing 100085, China,Pingliang Central Seismic Station of Earthquake Administration of Gansu Province, Pingliang 744000, Gamsu, China,Pingliang Central Seismic Station of Earthquake Administration of Gansu Province, Pingliang 744000, Gamsu, China,Longnan Central Seismic Station of Earthquake Administration of Gansu Province, Longnan 744000, Gamsu, China and Pingliang Central Seismic Station of Earthquake Administration of Gansu Province, Pingliang 744000, Gamsu, China
Abstract:In this paper, we study the relationship of the static periods and the concentration of radon by AlphaGUARD radon instrument under the state of vacuum. We found that the static periods and the radon concentrations range measured with the AlphaGUARD radon instrument is in accordance with the law of decay. The best stability time and the variation of the radon measurement were determined by AlphaGUARD and FD-125. The results show that the variation of radon values is relatively stable in the static time of 70min and the radon observation value is gradually decreased, which conform to the decay law of radon. The average relative deviation of the measured values by the two instruments is less than 10%, which may due to the system error of the two instruments and the inaccurate of FD-125 test. The results of these experiments are helpful for the application of AlphaGUARD in the earthquake research in future.
Keywords:AlphaGUARD radon instrument   FD-125 radon instrument   Quiet time   Comparative observation
本文献已被 CNKI 等数据库收录!
点击此处可从《震灾防御技术》浏览原始摘要信息
点击此处可从《震灾防御技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号